Impulse IM200 F18 manual Troubleshooting

Page 19

Troubleshooting

Normal Stage of Operation

SYMPTOM

POSSIBLE PROBLEMS

SERVICE

 

 

 

Tool operates properly, but fasteners do not

Work-contacting element requires adjustment.

Adjust work contacting element.

drive fully.

 

 

Fuel cell is low.

Check fuel cell and replace as required.

 

 

 

 

 

There may be loss of seal in combustion

Press work contacting element against

 

chamber.

workpiece for one minute. Pull trigger. If

 

 

fastener does not drive, there is a leak that

 

 

requires service.

 

 

 

Tool operates properly, but fasteners are

Work-contacting element is not adjusted

Adjust work-contacting element. Readjust

sometimes over-driven, and sometimes

properly for the type of material being

as required when material density or

under-driven.

fastened.

thickness of material being fastened

 

 

changes.

 

 

 

Tool operates, but no fastener is driven.

Wrong fasteners being used.

Use only fasteners meeting Paslode®

 

 

specifications. Check Fasteners and

 

 

Applications section for fastener types and

 

 

sizes recommended for use in Impulse tool.

 

 

 

 

Follower not properly engaged behind fastener

Position follower behind fastener strip and

 

strip.

engage strip.

 

 

 

 

Jammed fastener.

Clear jam.

 

 

 

Tool operates erratically or appears to be

Fuel cell is low.

Check fuel cell.

losing power - tool indicator light is green.

 

 

Spark plug wire is loose.

Check spark plug wire.

 

 

 

 

 

Air filter is dirty, causing tool to overheat.

Remove air filter and clean. Use soap and

 

 

water to remove stubborn debris.

 

 

 

 

Tool is dirty.

Clean tool.

 

 

 

Tool operated and drove fasteners, but

Built-up dirt and debris on driver blade or in

Clean driver blade and nose bore with

driver blade did not return to up position.

nose bore.

degreaser cleaner.

 

 

 

 

Tool is dirty.

Clean tool.

 

 

 

Combustion chamber does not drop after

 

Clean track or replace work-contacting

Work-contacting element is bent, or is dirty.

element.

tool cycles.

 

 

 

 

 

If nailer will not operate after following the above service directions, return the tool to an authorized Paslode® representative for service.

For the nearest Paslode® representative call 1-800-682-3428.

For Technical support call 1-800-222-6990.

An Illinois Tool Works Company 888 Forest Edge Drive Vernon Hills, Illinois 60061 www.paslode.com

Image 19
Contents Operating Manual Contents TrimMaster 18 Finish Nailer Operating Manual Introduction and WarrantyFor the nearest Paslode representative call 1-800 Description SpecificationsDimensions Weight-with battery An Overview of the Cordless TrimMaster 18 Finish NailerSafety Instructions AND/OR Work Contacting Element Pressed Never Assume the Tool is EmptyOr SQUEEZING, the Trigger Do not Load Fasteners with the TriggerKeep Your Hands Clear of the Work Area Surface Keep the Tool CleanBattery Disposal Never Drive Fasteners Into Areas with Concealed HazardsImportant Charging Notes Battery and Charging SystemBattery and Charging System First charge new battery HoursBattery Indicator Light Inserting BatteryHazard Fuel Cell and Metering ValveFuel Cell Metering ValveInstalling Metering Valve to Fuel Cell Prior to Use Inserting Fuel Cell Impulse and Outdoor Weather Preparing the TrimMaster 18 Finish Nailer for UseFasteners Loading FastenersTrimMaster 18 Finish Nailer Operation Depth of Drive AdjustmentTurn adjustment wheel in either direction Remove the battery before adjusting the depth of drivePack Fasteners and ApplicationsApplications Fuel Fastener Length ApplicationsClearing a Jam Restrict Field Service to the Following Fuel Cell CheckBattery Check ServicingEnd-of-Workday Routine Paslode Cordless Tool AccessoriesTinted Safety Glasses Part No Air FilterPreparing Tool for Operation Battery/Charger Problems TroubleshootingNormal Stage of Operation Troubleshooting Paslode Model Number Designation