Harbor Freight Tools 93760 operating instructions INSPECTION, MAINTENANCE, and Cleaning

Page 10

7.Make sure the Nose (40) moves freely.

8.Reload the Nailer with Nails. Then, reconnect the air supply hose to the tool.

9.Press the Nose (40) against a piece of scrap wood, and test fire the Nailer several times while checking for proper operation. If the Nailer is properly firing, you may continue using the tool. If the tool fails to perform properly, immediately discontinue use and have the tool repaired by a qualified service technician.

10.When finished working, disconnect the air supply. Remove the Nails. Then, store the Nailer in a clean, dry, safe location out of reach of children.

Anytime any maintenance or repairs are done, FIRST:

1.Disconnect the Nailer from its air supply.

2.Empty the Magazine Assembly (73) completely.

3.Attempt to fire the Nailer into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any Nails.

4.Always leave the Magazine Assembly (73) open during maintenance. The Magazine is spring loaded, and may cause parts or a Nail to fly out of the Nailer.

INSPECTION, MAINTENANCE, AND CLEANING

1.Inspect the air supply Screen that is located in the End Cap (84) before each use, and clean or replace as necessary. Dirt and water in the air supply Screen are major causes of pneumatic tool wear. Use a filter in the compressed air system for better performance and longer tool life. The filter must have adequate flow capacity for the specific application.

2.Clean the external parts of the Nailer with a clean cloth and mild detergent or non-flammable solvent. Then, dry.

3.Store the tool in a clean, dry, safe location out of reach of children.

4. CAUTION: All maintenance, service, or repairs not listed in this manual are only to be attempted by a qualified service technician.

SKU 93760 For technical questions, please call 1-800-444-3353 PAGE 10

Image 10
Contents Framing Nailer For technical questions, please callSave this Manual Product SpecificationsSafety Warnings and Precautions REV 11/06, 01/07 SKU For technical questions, please callSKU For technical questions, please call SKU For technical questions, please call California Health & Safety Code 25249.5, et seq UnpackingTesting the Full Sequential Safety Trip Mechanism OperationLoading Nails Do not exceed the maximum 125 PSI Operating the NailerFor technical questions, please call Rev 11/06 SKU Clearing Jams Remove the two Screws 35. One Screw on each side of MagazineINSPECTION, MAINTENANCE, and Cleaning Anytime any maintenance or repairs are done, FirstTroubleshooting Problem Possible SolutionParts List DescriptionAssembly Diagram Please Read the Following Carefully