Model W1815 (Mfg. Since 10/10)
Table Tilt Calibration
When the table is perpendicular to the sanding disc, the scale should read 0˚. If not, follow this procedure.
Tools Needed: |
|
Machinist's Square | 1 |
Phillips Head Screwdriver | 1 |
To calibrate the table tilt, do these steps: |
|
1. DISCONNECT MACHINE FROM POWER! |
|
2. Using a try square or machinist’s square, set one edge on the table surface and the other against the face of the disc, as shown in Figure 19.
Note: This can be done with the sandpaper installed, although it is somewhat more precise without the sandpaper.
3.Loosen the lock handles and adjust the table angle until it is perfectly perpendicular to the disc, then tighten the lock handles while holding the table in place.
4.Loosen the degree scale pointer, index the pointer on 0˚, then retighten the screw.