M1113 18" Wood/Metal Bandsaw
SETUP
Table Stop Adjustment
An adjustable table stop allows the table to easily return to 90˚ after tilting.
To set the table stop so the table is 90˚ to the blade, do these steps:
1.Make sure the blade is correctly tensioned as described in the Blade Tensioning instructions on
Page 19.
2.DISCONNECT BANDSAW FROM POWER!
3.Loosen the two table trunnion knobs.
4.Loosen the hex nut that locks the table stop bolt in place.
5.Raise the upper blade guide assembly and place a 6" machinist’s square or
6.Secure the knobs and lock the table stop bolt by tightening the hex nut against the casting. Ensure that the bolt does not turn by holding it with anoth- er wrench while tightening the hex nut.
�����
������
�����
Figure 31. Squaring table to blade.
Table Tilt Scale
Calibration
The pointer on the table tilt scale (Figure 32) must be calibrated in order for the scale reading to be accurate.
To calibrate the pointer on the table tilt scale, do these steps:
1.Make sure the blade is tensioned/tracking correctly and that the table is 90˚ to the blade (this proce- dure should be already completed with the Table Stop Adjustment instructions).
2.Loosen the pointer screw.
3.Align the tip of the pointer with the 0˚ mark on the table tilt scale.
4.Tighten the pointer screw.
Pointer