3.Press the [+] or [-] key to change interval.
4.Press the [AUTO] and [TRUE] keys to- gether more than two seconds to return to the normal mode. The STATUS LED blinks while the equipment is being calibrated and lights when the calibration is completed (re- turn to normal mode). Do not operate the equipment while the LED is blinking; cali- bration will be incomplete.
Setting the output sentence(s)
Select which type(s) of heading data to output. The default setting is HDG.
1.Disconnect the power connector from the sensor.
2.Reattach the connector to the sensor while pressing the
AUTO TRUE CALIB STATUS
4.Press the [AUTO] and [TRUE] keys to- gether more than two seconds to return to the normal mode. The STATUS LED blinks while the equipment is being calibrated and lights when the calibration is completed (re- turn to normal mode). Do not operate the equipment while the LED is blinking; cali- bration will be incomplete.
sentence HDG HDT HDM HCC
:On (current selection) :Off
HDG : Magnetic heading,
Magnetic variation value
HDT : True heading
HDM : Magnetic heading
HCC : Compass heading
Figure 17 LED and output sentence
3.Press key(s) corresponding to sentence(s) to output. For example, press the [TRUE] key to output HDT.
Note 1: Several sentences may be output simultaneously. However, delay may result when the output interval is 100 ms or 200 ms.
Note 2: "HDT" outputs true heading data. However, if variation data is not input from the GPS navigator, magnetic bearing will be output.
7