Furuno PG-1000 manual Mounting, Press the Auto and + keys together more than two seconds

Page 10

5.Press the [AUTO] and [+] keys together more than two seconds.

AUTO TRUE CALIB STATUS

CALIBRATION

AUTO TRUE

INTEGRATED HEADING SENSOR

PG-1000

Figure 5 Key and LEDs

After the TRUE, CALIB and STATUS LEDs light and AUTO LED blinks, rotate the equipment 360º slowly, keeping it uplight. If three LEDs are lighting, the mounting location is suitable

AUTO TRUE CALIB STATUS

: On

: Blinking

Figure 6

If one or more LED is off, the mounting location is not suitable. Try to change the location, and do step 5 again.

6.Press the [AUTO] and [TRUE] keys to- gether to return to the normal mode. The STATUS LED blinks while the sensor is be- ing calibrated and lights steady when the calibration is completed. Do not operate the sensor while the LED is blinking; calibra- tion will be incomplete.

1.3Mounting

1.Fix the sensor by using screws and washers (supplied). The size of the fixing hole is ø 4.5 mm.

Ship's bow

Bow mark

fixing hole

130

65

 

.5 5

141 152

This line should be at right angles to the fore and aft line.

Material: Brass

o All dimensions in mm.

o For added support, use nuts, bolts and washers.

o Secure sufficient clearance around the sensor for maintenance and checking.

Figure 7 Mounting the PG-1000

Note: Do not overtighten the screws or bolts; the sensor may crack.

3

Image 10
Contents Integrated Heading Sensor First Edition JUL Safety Instructions Foreword FeaturesWord to PG-1000 Owners Table of Contents System Configuration NmeaSpecifications of Integrated Heading Sensor Equipment List InstallationInstallation materials CP64-02000 Standard setConnect the PG-1000 to the battery as shown in right Selecting Mounting LocationMounting Press the Auto and + keys together more than two secondsGrounding ConnectionsChecking for inclination Connection of external equipmentCorrecting Magnetic Field Distortion Deviation LED status at successful CorrectionHeading Alignment Setting Output DataSetting output interval Key. For example, the hading output bySetting the output sentences Press the + or key to change intervalCorrecting Magnetic Anomalies Controls and Indications Turning the Power On/OffTurn the mains switch on Status LED blinks. About two minutesSelecting Output Data Format Automatic Distortion CompensationConnect Furuno GPS Navigator to PG Maintenance Maintenance & TroubleshootingTroubleshooting LED/KEY/ROM/RAM test Diagnostic testWhen the equipment finds error, LEDs do not light + keyDisplaying Program Version No LED state Program version noParts Location and List Page