3.3Diagnostic test

The PG-1000 has a self-test which checks the circuit board and keys for proper operation.

LED/KEY/ROM/RAM test

1.Disconnect the power cable from the equip- ment.

2.While pressing the [AUTO] key, reattach the power cable.

The test sequence is as below.

AUTO TRUE CALIB STATUS

LED lights one by one from the left-side.

Blink twice.

All LEDs go off.

: On

: Blinking

: Off

Figure 22 Sequence of LED test

3. Press each key one by one.

LED corresponding to the key lights if the key is normal.

[AUTO] key: AUTO LED

[TRUE] key: TRUE LED

[-] key:

CALIB LED

[+] key:

STATUS LED

4.Press the [AUTO] and [TRUE] keys to- gether more than two seconds after check- ing all keys. Then, the ROM and RAM are checked.

AUTO LED lights: RAM is normal.

TRUE LED lights: ROM is normal.

5.Press the [AUTO] and [TRUE] keys to- gether more than two seconds to escape from the test. The STATUS LED blinks while the equipment is being calibrated and lights when the calibration is completed (re- turn to normal mode). Do not operate the sensor while the LED is blinking; calibra- tion will be incomplete.

EEPROM/Sensor test

This test checks the EEPROM and sensor. All default settings (navigation setting, output sen- tence, output interval, etc.) are restored at the completion of the test. Do this test after dis- mounting the equipment.

1.Disconnect the power cable off from the equipment.

2.While pressing the [TRUE] key, reattach the cable. All LEDs go off.

3.After AUTO LED lights, turn the equipment through a circle slowly instead of ship's movement until TRUE LED lights. The test proceeds in the sequence shown below.

When the equipment finds error, LEDs do not light.

AUTO TRUE CALIB STATUS

Start

EEPROM:

OK

Mag. sensor: OK

Angle sensor: OK

Rate sensor: OK

: On (normal)

: Off (error)

Figure 23 EEPROM/Sensortest sequence

11

Image 18
Contents Integrated Heading Sensor First Edition JUL Safety Instructions Features ForewordWord to PG-1000 Owners Table of Contents System Configuration NmeaSpecifications of Integrated Heading Sensor Equipment List InstallationInstallation materials CP64-02000 Standard setConnect the PG-1000 to the battery as shown in right Selecting Mounting LocationMounting Press the Auto and + keys together more than two secondsGrounding ConnectionsChecking for inclination Connection of external equipmentCorrecting Magnetic Field Distortion Deviation LED status at successful CorrectionHeading Alignment Setting Output DataSetting output interval Key. For example, the hading output bySetting the output sentences Press the + or key to change intervalCorrecting Magnetic Anomalies Controls and Indications Turning the Power On/OffTurn the mains switch on Status LED blinks. About two minutesAutomatic Distortion Compensation Selecting Output Data FormatConnect Furuno GPS Navigator to PG Maintenance & Troubleshooting MaintenanceTroubleshooting LED/KEY/ROM/RAM test Diagnostic testWhen the equipment finds error, LEDs do not light + keyDisplaying Program Version No LED state Program version noParts Location and List Page