TROUBLE | PROBABLE CAUSE |
| REMEDY | ||
|
|
|
|
|
|
|
|
|
|
|
|
Thermal overload | 1. Low voltage | 1. Check with voltmeter | |||
protector cuts out | 2. Clogged air filter | 2. Clean filter (see | |||
repeatedly |
|
| Maintenance section) | ||
| 3. Lack of proper ventila- | 3. Move compressor to well | |||
| tion/room temperature |
| ventilated area | ||
| too high |
|
|
|
|
| 4. Unit is plugged into | 4. Remove extension cord | |||
| extension cord |
|
|
|
|
|
|
| |||
Air tank pressure | 1. Loose connections (fit- | 1. Check all connections with | |||
drops when com- | tings, tubing, etc.) |
| soap and water solution | ||
pressor shuts off |
|
| and tighten | ||
| 2. Tank drain valve open | 2. Close valve | |||
| 3. Check valve leaking | 3. Disassemble check valve | |||
|
|
| assembly, clean or replace | ||
|
|
|
|
| |
|
|
| ! DANGER: |
|
|
|
| Do not disassemble | |||
|
| check valve with air in | |||
|
| tank; bleed tank | |||
|
|
|
| ||
Excessive moisture | 1. Excessive water in air | 1. Drain tanks | |||
in discharge air | tanks |
|
|
|
|
| 2. High humidity | 2. Move to area of less | |||
|
|
| humidity; use air line filter | ||
|
|
|
| ||
Compressor runs | 1. Defective pressure | 1. Replace switch | |||
continuously | switch |
|
|
|
|
| 2. Excessive air usage | 2. Decrease air usage; com- | |||
|
|
| pressor not large enough | ||
|
|
| for a requirement | ||
|
|
|
| ||
Compressor vibrates | Loose mounting bolts | Tighten | |||
|
|
|
| ||
Air output lower than | 1. Broken inlet valves | 1. Have authorized service | |||
normal |
|
| representative repair unit | ||
| 2. Intake filter dirty | 2. Clean or replace intake fil- | |||
|
|
| ter | ||
| 3. Connections leaking | 3. Tighten connections | |||
|
|
|
|
|
|
21