RIDGID OL90150 manual Handles. Used to move the compres Sor

Page 13

1.Belt Guard. The belt guard encloses the pulleys and drive belt. It protects the user from moving parts and directs cooling air to the compressor pump.

2.Air Filter. The air filter keeps dirt and debris from entering the compressor pump and reduces compressor noise.

3.Dipstick. The dipstick measures the oil level in the compressor pump.

Dipstick

9.Regulated Outlet Gauge. This gauge shows at-a-glance, air pressure at outlet. Air pressure is measured in pounds per square inch (PSI). Most tools have maximum pressure ratings. Never exceed the maximum pressure rating of the tool you are using. Be sure this gauge reads ZERO before changing air tools or disconnecting hose from outlet.

10.Regulator Knob. This knob controls air pressure to an air operated tool or paint spray gun. Turning the knob clockwise increases air pressure at the outlet. Turning counterclockwise

Add Oil

Max

Fill

Low Line

will lower air pressure at the outlet. Fully counterclockwise will shut off the flow of air completely.

Close Open

4.Handles. Used to move the compres-

sor.

5.Tank Drain Valve. The tank drain valve allows moisture to be removed from the tank.

NOTE: Each tank has its own tank drain valve.

6.On/Off Switch. This switch allows for manual control of the compressor. Note that when the switch is turned on, the compressor will automatically start and stop depending on tank pressure.

7.Air Storage Tanks. The tanks store air for later use.

8.Motor Voltage Selector Switch. Allows convenient voltage change from 120 volts to 240 volts.

11.Tank Pressure Gauge. Gauge shows pressure in air storage tanks indicat- ing compressor is building pressure properly.

12.ASME Safety Valve. This valve auto- matically releases air if the tank pres- sure exceeds the preset maximum.

13.Air Outlet Fittings. These fittings are 1/4” universal-style quick connect fit- tings and allow rapid tool changes.

13

Image 13
Contents Wheelbarrow AIR Compressor Table of Contents Safety Signal Words Safety InstructionsBefore Using the Air Compressor Safety Instructions Breathable Air Warning Spraying Precautions1000 General Electrical Connections Power Supply and Motor SpecificationsVolt, 60Hz Tool Information Motor Specifications Electrical RequirementsExtension Cords Changing Motor Voltage Thermal Overload Protector Glossary of TermsInstallation Unpacking and Checking ContentsAir Outlet Fittings Getting to Know Your Air CompressorHandles. Used to move the compres Sor Moisture in Compressed Air Operating Your Air CompressorLubrication Operating Your Air Compressor For Trouble-Free Operation Maintenance Tank Filter Removal, Inspection and ReplacementDrive Belt Storage Maintenance ScheduleTrouble Probable Cause Remedy TroubleshootingDo not disassemble Gasket is replaced with a Be sure that the old headNew one each time Head is removedTrouble Probable Cause Remedy Repair Parts Catalog Part Number Description Qty For Repair Parts, Call 1-800-4-RIDGIDRepair Parts Repair Kits Catalog No. OL90150 Model No. OL90150 Serial No RIDGID, INC