RIDGID R250SFA manual Troubleshooting, Problem Possible Cause Solution

Page 18

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

Air leak near the top of the tool or in the trigger area

Loose screws

Tighten screws

Worn or damaged O-rings or

Install Overhaul Kit

seals

 

Air leak near the bottom of the

Loose screws

Tighten screws

 

tool

Worn or damaged O-rings or bumper

Install Overhaul Kit

 

 

 

 

 

 

 

 

 

Tool does nothing or operates

Inadequate air supply

Verify adequate air supply

 

sluggishly

Inadequate lubrication

Lubricate tool

 

 

 

 

 

 

Worn or damaged O-rings or bumper

Install Overhaul Kit

 

 

 

 

 

 

Tool jams frequently

Incorrect fasteners

Verify that fasteners are the correct size

 

 

 

Damaged fasteners

Replace fasteners

 

 

 

Loose magazine

Tighten screws

 

 

 

Dirty magazine

Clean magazine

 

 

 

Worn or damaged driver

Install Driver Maintenance Kit

 

 

 

 

 

 

18

Image 18
Contents OPERATOR’S Manual R250SFATable of Contents IntroductionService General Safety RulesPersonal Safety Work AreaSpecific Safety Rules OperationAIR Supply and Connections Loading ToolSymbols Symbol Name DESIGNATION/EXPLANATIONGlossary of Terms Activate operating controlsFeatures Product SpecificationsQUICK-CONNECT Swivel Connector Adjustable ExhaustDepth of Drive Adjustment Know Your Finish NailerUnpacking AssemblyOperation Packing ListAdjusting the Exhaust Preparing the Tool for USEConnecting the Tool to AN AIR Supply Loading the Tool with Nails See Figures 6Using the Selectable Trigger Single Sequential Actuation ModeContact Actuation Mode Setting the AIR Pressure Drive Depth AdjustmentRemoving Nails from the Tool Clearing a Jammed Fastener Maintenance AccessoriesTroubleshooting Problem Possible Cause SolutionWarranty Customer Service Information