BP7384 Camden, CF3600 2/18/09 2:57 PM Page 8
15. Reinstall the hanger ball (Figure 8) on the downrod as follows. Route the motor leads through the downrod. Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
! WARNING
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
HANGER BALL |
|
PIN | CEILING |
DOWNROD | COVER |
SETSCREW
How to Hang
Your Ceiling Fan
! WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 9).
CEILING
AT
LEAST
7'
FLOOR
Figure 9
! WARNING
Figure 8
16. The fan comes with blue, black and white leads that are 80” long. Before installing fan, measure up approx- imately 6 to
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.
! WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 10).
8 | Model No.: CF3600 |