Agilent Technologies 665xA, 664xA Parts of a SCPI Message, 1.Command Message Structure, Headers

Page 10
Figure 2-1. Command Message Structure

 

 

 

 

 

 

Figure 2-1. Command Message Structure

The basic parts of the message in Figure 2-1 are:

Message Component

Example

Headers

VOLT LEV PROT CURR

Header Separator

The colon in VOLT:LEV

Data

4.5 4.8

 

Data Separator

The space in VOLT 4. 5 and PROT 4. 8

Message Units

VOLT:LEV 4.5 PROT 4.8 CURR?

Message Unit Separator

The semicolons in VOLT: LEV 4. 5; and PROT 4. 8;

Root Specifier

The colon in PROT 4. 8; : CURR?

Query Indicator

The question mark in CURR?

Message Terminator

The <NL> (newline) indicator. Terminators are not part of the SCPI syntax.

Parts of a SCPI Message

Headers

Headers (which are sometimes known as "keywords") are instructions recognized by the power supply interface. Headers may be either in the long form or the short form.

Long Form

The header is completely spelled out, such as VOLTAGE STATUS DELAY.

Short Form

The header has only the first three or four letters, such as VOLT STAT DEL.

Short form headers are constructed according to the following rules:

If the header consists of four or fewer letters, use all the letters. (DFI

DATA)

If the header consists of five or more letters and the fourth letter is not a vowel (a,e,i,o,u), use the first four

letters. (VOLTage

STATus)

If the header consists of five or more letters and the fourth letter is a vowel (a,e,i,o,u), use the first three letters.

(DELay CLEar)

You must follow the above rules when entering headers. Creating an arbitrary form, such as QUEST for QUESTIONABLE, will result in an error. The SCPI interface is not sensitive to case. It will recognize any case mixture, such as VOLTAGE,

Voltage, Volt, volt.

Note

Shortform headers result in faster program execution.

Remote Programming 11

Image 10
Contents Microfiche Part No PROGRAMMING GUIDE GPIB DC POWER SUPPLIESAgilent Part No JulySafety Guidelines Printing HistoryREMOTE PROGRAMMING ContentsGENERAL INFORMATION LANGUAGE DICTIONARYDescription of Subsystem Commands SCPI CONFORMANCE INFORMATION ERROR MESSAGESSTATUS REPORTING COMPATIBILITY LANGUAGEDocumentation Summary General InformationAbout this Guide User’s GuideDownloading and Installing the Driver Prerequisites for Using this GuideVXIplug&play Power Product Instrument Drivers Accessing Online HelpIntroduction To SCPI GPIB Capabilities Of The Power SupplyRemote Programming ConventionsStructure of a SCPI Message Types of SCPI CommandsSCPI Messages Common CommandsMessage Component Parts of a SCPI MessageFigure 2-1.Command Message Structure VOLT LEV PROT CURRMessage Unit Separator Traversing the Command TreeQuery Indicator Root SpecifierThe Effect of Optional Headers Figure 2-2.Partial Command TreeActive Header Path Moving Among SubsystemsValue Coupling Including Common CommandsSCPI Queries SCPI Data FormatsTable 2-2.Suffixes and Multipliers ExamplesListening Formats ClassEnable the output Controlling the OutputDisable the output Programming Voltage and CurrentWriting to the Display Saving and Recalling StatesProgramming Status Programming the Digital I/O Port System ConsiderationsThe GPIB Address A direct primary address and a secondary address Sample Program Code DOS DriversAgilent BASIC Controllers Error HandlingProgramming Some Power Supply Functions Controller Using Agilent 82335A InterfaceProgramming Some Power Supply Functions continued 22 Remote ProgrammingProgramming Some Power Supply Functions continued 24 Remote Programming Subsystem Commands Related CommandsCommon Commands Language DictionaryDescription Of Common Commands Figure 3-1.Common Commands Syntax DiagramDescription Meaning and Type0 to Related Commands ESR?IDN? Query SyntaxPower-onStatus Clear Device Initialization OPC?OPT? PSC 0 *PSCMeaning and Type DescriptionMeaning and Type STB? Bit Configuration of Status Byte RegisterTST? ABOR Description of Subsystem CommandsCalibration Commands Figure 3-2.Subsystem Commands Tree DiagramCURR PROT STAT Current SubsystemCURR CURR TRIG CURRENT:LEVEL 200 MADISP Display SubsystemDIG DATA Digital I/O Port Programming ChartDISP TEXT DEFAULT MODE DISP MODEDISP TEXT enclosed in either single ‘ or double quotesINIT INIT:CONT Initiate SubsystemMeasure Subsystem MEAS CURR? MEAS VOLT?OUTP PROT CLE OUTP PROT DEL Output SubsystemOUTP 0 orOUTP REL 1 OUTP REL OFF OUTP RELOUTP REL POL OUTP REL POL NORMStatus Operation Registers Status SubsystemSTAT PRES STAT OPER?STAT OPER NTR STAT OPER PTR STAT OPER ENABSTATUS OPERATION ENABLE? STAT:QUES:COND? Status Questionable RegistersSTAT QUES? STAT QUES ENABSYST ERR? System CommandsSTAT QUES NTR STAT QUES PTR corresponding Questionable Event registerSYST VERS? Trigger SubsystemSYST LANG TRIGVOLT VOLT TRIG Voltage SubsystemTRIG SOUR VOLTAGE LEVEL 200 MVCommand Summary Command SummaryVOLT:PROT CommandCommand Parameters Parameter Characteristics in the Operating GuideProgramming Parameters Agilent Model and ValueStatus Reporting Power Supply Status StructureRegister Commands Operation Status GroupFigure 4-1.Power Supply Status Model Table 4-2.Bit Configurations of Status RegistersSignal MeaningTable 4-3.Status Questionable Commands Questionable Status GroupStandard Event Status Group CLS *ESR?Determining the Cause of a Service Interrupt Service Request Enable RegisterInitial Conditions At Power On Status Byte RegisterTable 4-4.Default Power On Register States The PON Power-OnBitServicing an Operation Status Mode Event Caused ByServicing Questionable Status Events Monitoring Both Phases of a Status TransitionAdding More Operation Events Table 4-5.Generating RQS from the CC EventRI Remote Inhibit SCPI Command CompletionDFI Discrete Fault Indicator Techniques in ANSI/IEEE StdCalibration Error Messages Error MessagesPower Supply Hardware Error Messages System Error Messages60 Error Messages SCPI Conformance Information SCPI Confirmed Commands1SCPI Approved Commands SCPI VersionNON-SCPICommands1 Compatibility Language ARPS Command1 Table B-1.ARPS CommandsSimilar SCPI Table B-1.ARPS Commands continued Command Index 68 Index Page Latin America Agilent Sales and Support OfficeUnited States Canada
Related manuals
Manual 70 pages 51.66 Kb Manual 142 pages 24.05 Kb

668xA, 669xA, 667xA, 664xA, 665xA specifications

Agilent Technologies has long been a pioneer in the production of high-performance electronic test and measurement instruments, particularly in the field of power sources. Among its notable offerings are the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA series of power supplies. These instruments are designed to provide stable, reliable power for a variety of applications, including electronic testing, industrial processes, and research laboratories.

The Agilent 667xA series is characterized by its programmability and advanced measurement functions. These power supplies support a wide range of output voltages and currents, allowing for flexible configurations that cater to different testing needs. The built-in measurement capabilities enable users to monitor the voltage, current, and power with high precision, which is essential for ensuring optimal performance in electronic applications.

The Agilent 669xA series stands out with its high-power outputs, making it suitable for demanding applications. These power supplies deliver high voltage and current levels, making them ideal for testing high-performance devices, such as power amplifiers and motor drives. Additionally, the 669xA series includes features such as overvoltage protection and complex output sequencing to enhance the safety and reliability of the testing process.

The Agilent 665xA and 664xA series focus on delivering high accuracy and excellent regulation. These models are particularly known for their low noise operation, which is critical for sensitive applications where precision is paramount. The integrated programming capabilities allow users to automate testing sequences, thus improving efficiency in research and development settings.

The 668xA series features advanced digital signal processing that enhances the precision and stability of the output. Users benefit from features like remote sensing and monitoring, allowing feedback adjustments that maintain output accuracy despite cable losses. Furthermore, the 668xA models can integrate seamlessly with various test environments thanks to their LAN, GPIB, and USB connectivity options.

Overall, the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA power supplies provide a comprehensive range of solutions for diverse electronic testing needs. With their advanced features, superb measurement capabilities, and robust performance, these instruments empower engineers and researchers to conduct their work with confidence, precision, and efficiency.