Agilent Technologies 665xA, 664xA, 667xA, 669xA, 668xA manual Compatibility Language

Page 60
Compatibility Language

B

Compatibility Language

The Agilent Series 664xA, 665xA, 667xA, 668xA, and 669xA Power Supplies are programatically compatible with the Agilent 603xA Series AutoRanging Power Supplies (ARPS). This means that you can program the Agilent 664xA, 665xA, 667xA, 668xA, and 669xA supplies over the GPIB using the ARPS commands. Software that you have written for the autoranging power supplies can also be adapted to program the above supplies.

Note

The Agilent 664xA, 665xA, 667xA, 668xA, 669xA serial link is not supported by ARPS

 

commands. You can use only a GPIB primary address for the power supply.

 

 

To switch from SCPI commands to ARPS commands (and vice versa), use the SYST:LANG command. This command is documented in "Chapter 3 - Language Dictionary".

Table B-1 summarizes the ARPS commands that program the supplies. You will need to refer to the Series 603xA power supply manual1 for complete information on the ARPS commands. Some of the ARPS commands are similar to SCPI commands, but others are unique to ARPS. For example, the ARPS FOLD commands have no function with the Series 664xA, 665xA, 667xA, 668xA, and 669xA supplies. Similarly, there are some SCPI commands that have no ARPS function.

Note

Parallel Polling:

 

When programmed for parallel polling and Compatibility Language, power supplies operating under the

 

Agilent BASIC system can "hang up" the GPIB when the system is turned on. This can occur under the

 

following conditions:

The controller uses CS80 Protocol for an external disk drive (for example, the Agilent 9133D).

The external disk drive and the power supply have the same select code and that code is 7 or less.

The external disk drive and power supply addresses are binary complements of each other (e.g., 0 & 7, 1 & 6, etc.).

When the system is turned on, the power supply accesses the GPIB before the controller and prevents it from accessing the external disk drive. The solution is to change one of the GPIB addresses, or to ensure that the power supply is not turned on until after the controller has completed its selftest and has control of the GPIB.

1This manual is listed in the Chapter 1 "Replaceable Parts" table of the power supply Operating Guide.

Compatibility Language 63

Image 60
Contents PROGRAMMING GUIDE GPIB DC POWER SUPPLIES Agilent Part NoMicrofiche Part No JulySafety Guidelines Printing HistoryContents GENERAL INFORMATIONREMOTE PROGRAMMING LANGUAGE DICTIONARYDescription of Subsystem Commands ERROR MESSAGES STATUS REPORTINGSCPI CONFORMANCE INFORMATION COMPATIBILITY LANGUAGEGeneral Information About this GuideDocumentation Summary User’s GuidePrerequisites for Using this Guide VXIplug&play Power Product Instrument DriversDownloading and Installing the Driver Accessing Online HelpGPIB Capabilities Of The Power Supply Remote ProgrammingIntroduction To SCPI ConventionsTypes of SCPI Commands SCPI MessagesStructure of a SCPI Message Common CommandsParts of a SCPI Message Figure 2-1.Command Message StructureMessage Component VOLT LEV PROT CURRTraversing the Command Tree Query IndicatorMessage Unit Separator Root SpecifierFigure 2-2.Partial Command Tree Active Header PathThe Effect of Optional Headers Moving Among SubsystemsIncluding Common Commands SCPI QueriesValue Coupling SCPI Data FormatsExamples Listening FormatsTable 2-2.Suffixes and Multipliers ClassControlling the Output Disable the outputEnable the output Programming Voltage and CurrentSaving and Recalling States Writing to the DisplayProgramming Status System Considerations Programming the Digital I/O PortThe GPIB Address A direct primary address and a secondary address DOS Drivers Agilent BASIC ControllersSample Program Code Error HandlingProgramming Some Power Supply Functions Controller Using Agilent 82335A InterfaceProgramming Some Power Supply Functions continued 22 Remote ProgrammingProgramming Some Power Supply Functions continued 24 Remote Programming Related Commands Common CommandsSubsystem Commands Language DictionaryDescription Of Common Commands Figure 3-1.Common Commands Syntax DiagramMeaning and Type Description0 to ESR? IDN?Related Commands Query SyntaxOPC? OPT?Power-onStatus Clear Device Initialization PSC 0 *PSCMeaning and Type DescriptionMeaning and Type STB? Bit Configuration of Status Byte RegisterTST? Description of Subsystem Commands Calibration CommandsABOR Figure 3-2.Subsystem Commands Tree DiagramCurrent Subsystem CURR CURR TRIGCURR PROT STAT CURRENT:LEVEL 200 MADisplay Subsystem DIG DATADISP Digital I/O Port Programming ChartDISP MODE DISP TEXTDISP TEXT DEFAULT MODE enclosed in either single ‘ or double quotesInitiate Subsystem Measure SubsystemINIT INIT:CONT MEAS CURR? MEAS VOLT?Output Subsystem OUTPOUTP PROT CLE OUTP PROT DEL 0 orOUTP REL OUTP REL POLOUTP REL 1 OUTP REL OFF OUTP REL POL NORMStatus Subsystem STAT PRESStatus Operation Registers STAT OPER?STAT OPER ENAB STAT OPER NTR STAT OPER PTRSTATUS OPERATION ENABLE? Status Questionable Registers STAT QUES?STAT:QUES:COND? STAT QUES ENABSystem Commands STAT QUES NTR STAT QUES PTRSYST ERR? corresponding Questionable Event registerTrigger Subsystem SYST LANGSYST VERS? TRIGVoltage Subsystem TRIG SOURVOLT VOLT TRIG VOLTAGE LEVEL 200 MVCommand Summary VOLT:PROTCommand Summary CommandCommand Parameters Characteristics in the Operating Guide Programming ParametersParameter Agilent Model and ValuePower Supply Status Structure Register CommandsStatus Reporting Operation Status GroupTable 4-2.Bit Configurations of Status Registers SignalFigure 4-1.Power Supply Status Model MeaningQuestionable Status Group Standard Event Status GroupTable 4-3.Status Questionable Commands CLS *ESR?Service Request Enable Register Initial Conditions At Power OnDetermining the Cause of a Service Interrupt Status Byte RegisterThe PON Power-OnBit Servicing an Operation Status Mode EventTable 4-4.Default Power On Register States Caused ByMonitoring Both Phases of a Status Transition Adding More Operation EventsServicing Questionable Status Events Table 4-5.Generating RQS from the CC EventSCPI Command Completion DFI Discrete Fault IndicatorRI Remote Inhibit Techniques in ANSI/IEEE StdError Messages Power Supply Hardware Error MessagesCalibration Error Messages System Error Messages60 Error Messages SCPI Confirmed Commands1 SCPI Approved CommandsSCPI Conformance Information SCPI VersionNON-SCPICommands1 Compatibility Language Table B-1.ARPS Commands ARPS Command1Similar SCPI Table B-1.ARPS Commands continued Table B-1.ARPS Commands continued Index 68 Index Page Agilent Sales and Support Office United StatesLatin America Canada
Related manuals
Manual 70 pages 51.66 Kb Manual 142 pages 24.05 Kb

668xA, 669xA, 667xA, 664xA, 665xA specifications

Agilent Technologies has long been a pioneer in the production of high-performance electronic test and measurement instruments, particularly in the field of power sources. Among its notable offerings are the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA series of power supplies. These instruments are designed to provide stable, reliable power for a variety of applications, including electronic testing, industrial processes, and research laboratories.

The Agilent 667xA series is characterized by its programmability and advanced measurement functions. These power supplies support a wide range of output voltages and currents, allowing for flexible configurations that cater to different testing needs. The built-in measurement capabilities enable users to monitor the voltage, current, and power with high precision, which is essential for ensuring optimal performance in electronic applications.

The Agilent 669xA series stands out with its high-power outputs, making it suitable for demanding applications. These power supplies deliver high voltage and current levels, making them ideal for testing high-performance devices, such as power amplifiers and motor drives. Additionally, the 669xA series includes features such as overvoltage protection and complex output sequencing to enhance the safety and reliability of the testing process.

The Agilent 665xA and 664xA series focus on delivering high accuracy and excellent regulation. These models are particularly known for their low noise operation, which is critical for sensitive applications where precision is paramount. The integrated programming capabilities allow users to automate testing sequences, thus improving efficiency in research and development settings.

The 668xA series features advanced digital signal processing that enhances the precision and stability of the output. Users benefit from features like remote sensing and monitoring, allowing feedback adjustments that maintain output accuracy despite cable losses. Furthermore, the 668xA models can integrate seamlessly with various test environments thanks to their LAN, GPIB, and USB connectivity options.

Overall, the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA power supplies provide a comprehensive range of solutions for diverse electronic testing needs. With their advanced features, superb measurement capabilities, and robust performance, these instruments empower engineers and researchers to conduct their work with confidence, precision, and efficiency.