Emerson CF200n100 PIN Hanger Ball Downrod Setscrew, Hairpin Clip, Setscrew Motor, Clevis PIN

Page 7

BP7354 CF200 9/19/07 11:30 AM Page 7

9. Carefully remove the fan assembly from the lower foam pad. Turn the fan assembly over and position it on the lower foam pad with the fan blades resting on the pad so that the top of the motor faces up.

10. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 7). Remove th pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for rein- stallation in step 18.

PIN

HANGER

BALL

DOWNROD

SETSCREW

Figure 7

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tight- ened. Failure to verify that the pin and setscrews are properly installed (as shown in Figure 8) could result in the fan falling.

HAIRPIN

CLIP

 

DOWNROD

SETSCREW (2)

MOTOR

COUPLING

CLEVIS PIN

NOTE: If you have an eight-foot ceiling, you will have to use the 6” downrod (supplied) in order to maintain the nec- essary blade-to-floor clearance of seven feet.

11. Unscrew the two upper setscrews (Figure 8) until they clear the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 8). The clevis pin must go through the holes in the motor cou- pling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull up on the downrod to make sure the clevis pin is properly installed.

Figure 8

12.Tighten the setscrews (Figure 8) securely while pulling up on the downrod.

NOTE: The setscrews must be properly installed as described above, or fan wobble could result.

13.Make sure the grommet Is properly installed in the coupling cover, then slide the coupling cover over the downrod until it rests on the motor housing. (Figure 9).

NOTE: If you installed the 6” downrod, the three decorative rod assemblies and the rod support assembly will not be installed. Disregard steps 14 through 17; proceed to step 18.

14.Make sure the grommets are properly installed in the rod support assembly. Then position the three screws in the rod support toward the top, and slide the rod support over the downrod (Figure 9).

7

U.L. Model No.: CF200

Image 7
Contents Cityscape Date Code Safety InstructionsMaterials Tools Needed for AssemblyUnpacking Instructions General Preset Memory FeatureInstallation of Battery Setting Operating Frequency of Transmitter ReceiverElectrical Requirements How to Assemble Your Ceiling FanBlade Flange Motor HUB Light Fitter White Wires Black Wire BlueSwitch Housing Assembly Connector Switch Housing AssemblyClevis PIN PIN Hanger Ball Downrod SetscrewHairpin Clip Setscrew MotorScrews Motor Cover Housing Decorative ROD ScrewDecorative ROD Assembly ROD Support GrommetTAB How to Hang Your Ceiling FanCeiling AT Least Floor Outlet BOX TWO Screws Supplied WithStud How to Wire Your Ceiling FanCeiling Cover BlackWhite Ground RED Black BlueReversing Switch Installation Storage BracketOperating Your Ceiling Fan Important Care Instructions MaintenanceAccessoriesTrouble Probable Cause Suggested Remedy Trouble ShootingDescription Repair Parts ListingLimited Warranty

CF200n100 specifications

The Emerson CF200N100 is a cutting-edge fan controller designed to provide optimal air circulation and temperature control in various environments. Known for its efficiency and advanced features, this model has found applications in residential, commercial, and industrial settings.

One of the standout characteristics of the CF200N100 is its energy efficiency. Designed to operate with minimal power consumption, this unit helps reduce electricity costs while maintaining effective airflow. It integrates advanced technologies that allow for precise control over fan speed, facilitating customized air distribution according to specific needs.

The CF200N100 employs a microprocessor-based control system that enhances stability and reliability. This technology allows for intelligent programming, enabling users to set specific temperature thresholds and operational schedules. With a user-friendly interface, the controller simplifies adjustments and makes it convenient to monitor performance.

Another significant feature of the Emerson CF200N100 is its compatibility with various fan types and setups. Whether used in ducted systems or standalone fans, the controller can adapt to different configurations, making it a versatile choice for any installation. Its flexibility also extends to integration with existing HVAC systems, providing seamless functionality in retrofitting scenarios.

The unit showcases various safety features, including overcurrent protection and temperature monitoring, ensuring that both the device and connected fans operate within safe limits. This not only prolongs the lifespan of the equipment but also enhances user peace of mind.

For communication, the CF200N100 is equipped with advanced connectivity options, allowing for integration with smart home systems. Users can control fan settings remotely, making adjustments from anywhere through compatible devices. This capability not only adds convenience but also allows for real-time monitoring of environmental conditions.

The design of the Emerson CF200N100 is compact, ensuring that it can be installed in tight spaces without compromising performance. Its robust construction contributes to its durability, ensuring that it withstands the demands of continuous operation.

In summary, the Emerson CF200N100 is a feature-rich fan controller that promises efficiency, flexibility, and advanced control. Its energy-saving technologies, user-friendly design, and integration options make it an excellent choice for anyone looking to improve their air circulation systems. Whether for residential use or in more demanding commercial settings, the CF200N100 stands out as a reliable solution in modern climate control management.