Sterling D48160s manual Replace the Downstroke BED Knife, Replace the Downstroke Knife Shields

Page 41

SETTINGS AND ADJUSTMENTS

SECTION 4-6

Adjusting or Replacing Bed Knives

REPLACE THE DOWNSTROKE BED KNIFE

Install the down-stroke bed knife (located on the near side of the rotor) making sure to install it with the knife- edge on the upper side.

Engage the captive screws in the slots on the near side of the knife bed and lower the knife onto the knife bed. Repeat these steps for the second half of the down-stroke knife.

REPLACE THE DOWNSTROKE KNIFE SHIELDS

Back off the captive screws on both halves of the bed knife so that they will not interfere with the rotor. Place the shields over the bed knife.

Install the mounting screws and washers and tighten them finger-tight.

CHECK THE BED KNIVES

Check both halves of the upstroke knife (the bed knife on the far side of the rotor) to be sure that the cutting edges face down.

Check both halves of the down-stroke knife (the bed knife on the near side of the rotor) to be sure that the cutting edges face up.

GAP ADJUSTMENT TIPS

It is best to keep the adjustments on the captive screws moving in the same direction. This eliminates the effect of backlash in the adjusting screw.

Make the screw adjustments in small steps to keep the bed knife adjustment even over the width of the machine.

To avoid cutting the shim stock, turn the rotor backward during the adjustment procedure.

Use the rotor knife with the largest dimension from rotor centerline as the reference, i.e., the highest knife.

41

Image 41
Contents Sterling,Inc Sterling, Inc Refer to this Sheet When Ordering PartsTable of Contents Settings and Adjustments Topic SECTION/PAGE Table of Contents Operation Adjustable Rotor Knives…………………………………………………………………4-35From previous MaintenanceTroubleshooting MaintenanceParts Lists and Drawings Page Introduction What is a GRANULATOR?Section Learn Machine SafetyRotating Knives Safety Plate Follow the Safety InstructionsOpening Hopper Safety Plate Jackscrew Reversing Operation Guards Safety PlateHazardous Voltage Safety Plate Safety Instruction PlateMotor Rotation Safety Plate Rotating Knives Safety PlateSafety Clothing & Practices Keep CO-WORKERS OFF the Machine Wear Protective ClothingKeep Your Work Area Safe Be Sure the Rotor is Motionless Before Opening Machine Machine Opening DevicesOpen the Cutting Chamber SectionRestart the Granulator Clear the JAMMachine and Controls BP 2400 Series Granulator Right Front Quarter View BP 2400 Series Granulator Left Rear Quarter View Uncrate the Granulator Section OverviewLevel the Granulator Section Move the Granulator to ITS Work SiteAllow Adequate Work Space Remove the Protective Coating Electrical Wiring Check Rotation of Motors SET UP the Machine FunctionsSection Check for Mechanical Interferences Alternate Test for the Interlock Switches Interlock Switch Test ProcedureInstallation Test the Zero Speed Sensor Alternate Test for the Interlock Switches from previousTest the Zero Speed Sensor LubricationSettings and Adjustments See -10 page 87 for Cutting Chamber Opening Instructions Open the Cutting Chamber InterlockRelease the Cutting Chamber Fasteners Install the Rotor Locating PIN Remove the First Knife Clamp or Shield Loosen the Mounting ScrewsRemove the BED Knives Replace the Upstroke Knife Clamp Replace the Upstroke BED KnifeReplace the Downstroke BED Knife GAP Adjustment TipsReplace the Downstroke Knife Shields Check the BED KnivesSET the Downstroke Knife Shield Measure the Knife GAPCheck the Knife GAP See -11 page 88 for Cutting Chamber Closing Instructions Finalize Installation of Upstroke BED KnifeTighten the Screws to Final Torque Fasten the Cutting Chamber Close the Cutting Chamber Safety InterlockBasic Facts about the Knives See -10 page 87 for Cutting Chamber Opening Instructions Remove the Rotor Knives Lock the RotorRemove the Mounting Screws Photo Clean Parts for ReassemblyMeasure the Knife GAP GAP Adjustment TipsTighten the Screws to Final Torque Check the Knife GAPFasten the Cutting Chamber Remove the Drive Guard Cover Inspect the Drive Belts Install the Matched BeltsRemove the Belts Tighten the Belt TensionMeasure the Belt Span Check the Pulley AlignmentCalculate the Allowable Belt Deflection Measure the Deflection ForceTighten the Motor Base Bolts Adjust the Belt TensionCompare Measured Force to Recommended Force Replace the Drive Guard Cover Setting and Adjusting the Chamber Jackscrew Cutting Chamber Open Setpoint Adjust the Jackscrew OPEN-POSITION Limit Switch If the Motor Stops Before the Cutting Chamber Closes SET the Jackscrew CLOSED-POSITION Limit SwitchChamber Stops Before IT Closes but Motor Continues to RUN SET & Test the Mounting Bracket Limit SwitchSET the Jackscrew CLOSED-POSITION Limit From previous Close the Cutting Chamber Safety Interlock Retract the Screen Cradle Retainers Cradle Open Position Adjust the Cradle OPEN-POSITION Limit Switch Check the Cradle CLOSED-POSITION Switch Close the Screen Cradle Interlock Adjust the Cradle CLOSED-POSITION Limit SwitchClose the Screen Cradle Retainers Zero Speed Sensor Adjust the Sensor PositionZero Speed Sensor Operation Control CircuitRotor Knife Preparation Rotor Knife Installation Into FixtureKnife Length Setting Adjustable Rotor Knife Installation Knife Length SETTING-INSPECTIONHydraulic Pump Operation Hydraulic Opening Position SwitchesOperation RUN the Motor Discharge AIR AdjustmentCheck the Motor Rotation Direction Shut Down the Machine Cleaning the Discharge TransitionSafely Clearing a Jam Maintenance Check Daily Weekly Monthly Periodic Maintenance ScheduleScreen Condition Knife Screw TorqueBelt Tension Upper Chamber Pivot ARM-SCREWS Infeed Flap ConditionRetract the Screen Cradle Retainers Open the Screen Cradle InterlockSee -12 page 90 for Screen Cradle Lowering Instructions Replace the Screen Remove the ScreenMaintenance Close the Screen Cradle Interlock Cutting Chamber Access Open the Cutting Chamber with Hydraulics Open the Cutting Chamber with JackscrewsClose the Cutting Chamber with Jackscrews Fasten the Cutting Chamber Lower Raising the Screen Cradle with Jackscrews Rotor Knife Sharpening BED Knife Sharpening Locating Trouble Troubleshooting ChartTest Equipment Section Mechanical Faults Electrical Faults Problem Probable Cause RemedyBP2400 Series Parts List and Drawings 100 Parts Identification Drawing No. A-48050 Sheet 3 Parts Identification Drawing No. A-48050 Sheet 4 Parts Identification Drawing No. A-48150 Sheet 1 Parts Lists and Drawings Parts Identification Drawing No Sheet 1 Parts Identification Drawing No -460 Sheet 1 Wiring Diagram Drawing No. A-399598 Sheet 1 108 Drawing No -1 Sheet 1 Wiring Diagram for Hydraulics Drawing No. D-499061 Sheet 1 Wiring Drawing No. D-499044 Sheet 1 112 113