MAINTENANCE
SECTION 6-9
Cutting Chamber Access
TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI
If it is not possible to lock out the power, have an electrician remove the fuses.
Make sure the rotor has come to a complete stop.
The hydraulic cylinders/jackscrews, which open the machine, should not operate until the rotor is completely stopped. If you discover that the jackscrews DO operate while the rotor is still turning, immediately shut down the machine and call for maintenance to adjust it.
Wear gloves to protect against injury from the rotor or bed knives.
OPEN THE CUTTING CHAMBER INTERLOCK
Disengage the interlock actuator screw with a box wrench or a ratchet wrench.
Make sure the end of the interlock actuator screw is visible and clear of any contact.
When disengaged, the interlock opens the electrical control circuit to the motor and prevents the machine from running.
RELEASE THE CUTTING CHAMBER
FASTENERS
Turn the
Swing the
86