Hobart Welding Products OM-240 438B Fumes and Gases can be hazardous, Noise can damage hearing

Page 6

FUMES AND GASES can be hazardous.

Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.

DIf ventilation is poor, wear an approved air-supplied respirator.

DRead and understand the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.

DWork in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watch- person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath- ing air is safe.

DDo not weld in locations near degreasing, cleaning, or spraying op- erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.

BUILDUP OF GAS can injure or kill.

D Shut off shielding gas supply when not in use.

DAlways ventilate confined spaces or use ap- proved air-supplied respirator.

ARC RAYS can burn eyes and skin.

Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.

DWear an approved welding helmet fitted with a proper shade of filter lenses to protect your face and eyes from arc rays and sparks when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).

DWear approved safety glasses with side shields under your helmet.

DUse protective screens or barriers to protect others from flash, glare, and sparks; warn others not to watch the arc.

DWear protective clothing made from durable, flame-resistant mate- rial (leather, heavy cotton, or wool) and foot protection.

WELDING can cause fire or explosion.

Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece,

and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.

DRemove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers.

DDo not weld where flying sparks can strike flammable material.

DProtect yourself and others from flying sparks and hot metal.

DBe alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas.

DWatch for fire, and keep a fire extinguisher nearby.

DBe aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side.

DDo not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards).

DDo not weld where the atmosphere may contain flammable dust, gas, or liquid vapors (such as gasoline).

DConnect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock, sparks, and fire haz- ards.

DDo not use welder to thaw frozen pipes.

DRemove stick electrode from holder or cut off welding wire at contact tip when not in use.

DWear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap.

DRemove any combustibles, such as a butane lighter or matches, from your person before doing any welding.

DAfter completion of work, inspect area to ensure it is free of sparks, glowing embers, and flames.

DUse only correct fuses or circuit breakers. Do not oversize or by- pass them.

DFollow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B for hot work and have a fire watcher and extinguisher nearby.

NOISE can damage hearing.

Noise from some processes or equipment can dam- age hearing.

DWear approved ear protection if noise level is high.

ELECTRIC AND MAGNETIC FIELDS (EMF) can affect Implanted Medical Devices.

D Wearers of Pacemakers and other Implanted

Medical Devices should keep away.

DImplanted Medical Device wearers should consult their doctor and the device manufacturer before going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations.

CYLINDERS can explode if damaged.

Shielding gas cylinders contain gas under high pres- sure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully.

DProtect compressed gas cylinders from excessive heat, mechani- cal shocks, physical damage, slag, open flames, sparks, and arcs.

DInstall cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping.

DKeep cylinders away from any welding or other electrical circuits.

DNever drape a welding torch over a gas cylinder.

DNever allow a welding electrode to touch any cylinder.

DNever weld on a pressurized cylinder — explosion will result.

DUse only correct shielding gas cylinders, regulators, hoses, and fit- tings designed for the specific application; maintain them and associated parts in good condition.

DTurn face away from valve outlet when opening cylinder valve.

DKeep protective cap in place over valve except when cylinder is in use or connected for use.

DUse the right equipment, correct procedures, and sufficient num- ber of persons to lift and move cylinders.

DRead and follow instructions on compressed gas cylinders, associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards.

OM-240 438 Page 2

Image 6
Contents OM-240 438B ProcessesDescription From Hobart to You Protect Your Investment Table of Contents 10-3 10-110-2 11-1Electric Shock can kill Symbol UsageArc Welding Hazards HOT Parts can burnARC Rays can burn eyes and skin Fumes and Gases can be hazardousBuildup of GAS can injure or kill Welding can cause fire or explosionEngine Hazards Hydraulic HazardsHydraulic Fluid can injure or kill Use only genuine replacement parts from the manufacturerCompressed Air Hazards Compressed AIR Equipment can injure or killFalling Equipment can injure Welding Wire can injureFire or Explosion hazard Overheating can damage motorsRadiation can cause interference Principal Safety Standards EMF InformationCalifornia Proposition 65 Warnings ARC Welding can cause interferenceUN Choc Électrique peut tuer Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation Indique des instructions spécifiquesLE Soudage peut provoquer un incendie ou une explosion LES Pièces Chaudes peuvent provoquer des brûluresLES Fumées ET LES GAZ peu- vent être dangereux LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peut provoquer des blessures Les Pièces Mobiles peuvent causer des blessuresLA Chaleur DU Moteur peut pro- voquer un incendie Les Pièces Mobiles peuvent causer des blessuresLire LES Instructions LA Chute DE L’ÉQUIPEMENT peut provoquer des blessures Risque D’INCENDIE OULES Fils DE Soudage peuvent provoquer des blessures LE Surchauffement peut endommager le moteur électriqueProposition californienne 65 Avertissements Principales normes de sécuritéLE Soudage À L’ARC risque de provoquer des interférences Informations relatives aux CEM En ce qui concerne les implants médicauxWeld, Power, and Engine Specifications − SpecificationsSymbol Definitions − DefinitionsDimensions, Weights, And Operating Angles Complete Parts List is available at wwwHobartWelders.comWeight 562 lb 254 kg Duty Cycle Dimensions For Units With Optional Running GearDimensions Welding AmperesFuel Consumption Subaru-Powered Units Fuel Consumption Kohler-Powered UnitsFor CC/DC Mode Generator Power CurveFor CC/AC Mode Volt-Ampere Curves− Installation Installing Welding GeneratorSerial Number And Rating Label Location Grounding Generator To Truck Or Trailer Frame Engine Prestart Checks Subaru-Powered Units Oil CheckOil Engine Prestart Checks Kohler-Powered Units FullTo improve cold weather starting Connect negative − battery cable last Installing Exhaust PipeConnecting Or Replacing the Battery + − + −Connecting To Weld Output Terminals Stop engine Failure to properly connectTools Needed 3/4 350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 m Selecting Weld Cable Sizes150 ft 200 ft 250 ft 100 150 200 250Front Panel Controls Engine Control Switch− Operating the Welding Generator Fine ControlLoaded Cold Weather Engine OperationInfrequently FrequentlyTypical Stick Welding Connections And Control Settings Stop engineElectrode − Operating Auxiliary Equipment Standard ReceptaclesCurrent Available in Amperes 240 Simultaneous Weld And PowerWiring Optional 240 Volt Plug Receptacle− Maintenance SUBARU-POWERED Units Maintenance Label Subaru-Powered Units100 Routine Maintenance Subaru-Powered UnitsStop engine before maintaining 200Servicing Air Cleaner Subaru-Powered Units Servicing Optional Spark Arrestor Subaru-Powered UnitsStop engine and let cool Oil Fill Oil Check Oil Drain Valve Oil FilterAdjusting Engine Speed Subaru-Powered Units Idle Speed AdjustmentOverload Protection Subaru-Powered Units Stop engine. Disconnect negative − battery cableFuse F1 See Section − Maintenance − KOHLER-POWERED Units Maintenance Label Kohler-Powered UnitsRoutine Maintenance Kohler-Powered Units Hours Nl Weld Cables ~ Slip Rings Nl Brushes OM-240 438Servicing Air Cleaner Kohler−Powered Units Close valve and valve cap Stop engine and let cool Oil Drain Valve2 ID x 7 in Hose Oil Filter Full Before adding oil Running engineLoosen lock nut. Turn adjustment Adjusting Engine Speed Kohler-Powered UnitsAdjustment Nut Turn idle speed screw for fine ad- justmentsOverload Protection Kohler-Powered Units Servicing Optional Spark Arrestor Kohler-Powered UnitsIf a fuse opens, it usually indi Generator Power Troubleshooting − TroubleshootingWelding Troubleshooting Trouble RemedyEngine Troubleshooting Check receptacle wiring and connectionsCheck fuel level Recommended Spare Parts − Parts ListControl switch S2, and throttle solenoid TS1 Recommended Spare PartsSOCKET/WRENCH Selection Table Standard Metric − Electrical Diagrams Circuit Diagram For Welding Generator240 424-A − Generator Power Guidelines Selecting EquipmentUse ground device as stated Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Electrical codesIndustrial Motors Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsSingle-Phase Induction Motor Starting Requirements Power Required To Start MotorHow Much Power Can Generator Supply? KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Tional, state, and local codesSelecting Extension Cord Use Shortest Cord Possible Electrode touches work Stick Welding Procedure− Stick Welding Smaw Guidelines Tools Needed Equipment Needed Piece Weld current can damageScratch Technique Electrode and Amperage Selection ChartStriking an Arc Tapping TechniquePositioning Electrode Holder Poor Weld Bead CharacteristicsGood Weld Bead Characteristics Groove Welds Fillet WeldsConditions That Affect Weld Bead Shape Electrode Movement During WeldingElectrode Angle Butt Joints Lap JointTee Joint To 3 51-76 mm .4 mm TroubleshootingWeld Test Possible Causes Corrective ActionsLack of Penetration Good Penetration Good Penetration Excessive PenetrationMetal remains OM-240 438 OM-240 438 OM-240 438 Service SupportAssistance Contact your Distributor for Hobart Welding Products