5-7. Electrical Service Guide
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Circuit Breaker 1,
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 1999 National Electrical Code (NEC)
1Choose a circuit breaker with
2
230
24
25
35
14
55
(17)
14
3“Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).
5-8. Installing Wire Spool And Adjusting Hub Tension
Installing 4 in (102 mm) Wire Spool
When a slight force is needed to turn spool, tension is set.
Installing 8 in (203 mm) Wire Spool | Adapter used with |
| |
| 8 in (203 mm) |
| spool only. |
When a slight force is needed to turn spool, tension is set.
Retaining ring used with 8 in (203 mm) spool only.
Tools Needed:
1/2 in
803 012 / 803 013