Troubleshooting (continued)
Motor (continued)
Trouble |
| Probable Cause |
| Remedy |
|
|
|
|
|
|
|
|
|
|
Starting switch in | 1. | Burned switch con- | 1. | Have switch replaced and request |
motor will not oper- |
| tacts (due to |
| a voltage check from the power |
ate. |
| extended |
| company. |
|
| ods caused by low |
|
|
|
| line voltage, etc.) |
|
|
| 2. | Shorted capacitor | 2. | Have capacitor tested and replace |
|
|
|
| if defective. |
| 3. | Loose or broken con- | 3. | Have wiring checked and repaired. |
|
| nections. |
|
|
|
|
|
|
|
Motor stalls | 1. | Starting switch not | 1. | Have switch replaced. |
(resulting in blown |
| operating. |
|
|
fuses or tripped circuit | 2. | Voltage too low to | 2. | Request voltage check from the |
breakers). |
| permit motor to reach |
| power company. |
|
| operating speed. |
|
|
| 3. | Fuses or circuit break- | 3. | Install proper size fuses or circuit |
|
| ers do not have suffi- |
| breakers. |
|
| cient capacity. |
|
|
|
|
|
|
|
Frequent opening of | 1. | Motor overloaded. | 1. | Take shallower cuts. |
fuses or circuit break- | 2. Fuses or circuit break- | 2. | Install proper size fuses or circuit | |
ers. |
| ers do not have suffi- |
| breakers. |
|
| cient capacity. |
|
|
| 3. | Starting switch not | 3. | Have switch replaced. |
|
| operating (motor does |
|
|
|
| not reach speed). |
|
|
|
|
|
|
|