Carrier 50VS specifications A50-8296, Cabinet, 16 x, 14 x, 12 x

Page 5

A

a50-8296

W

5/8"

C

H B

D

3 1/8"

DIMENSIONAL DATA

Grille Size (in.)

Cabinet

W (in.)

H (in.)

A (in.)

B (in.)

C (in.)

D (in.)

Height

 

 

 

 

 

 

 

16 x 14

STD

153/16

133/16

173/4

153/4

N/A

47/8

14 x 12

STD

133/16

113/16

153/4

133/4

67/8

N/A

12 x 10

STD

113/16

93/16

133/4

113/4

57/8

N/A

10 x 8

STD

93/16

73/16

113/4

93/4

47/8

N/A

NOTES:

1.The opposed blade damper allows control of air volume (cfm) and path of discharge air. Recommended for applica- tions requiring unequal airflow or side discharge grille(s) with additional top discharge air opening.

2.Dimensions are in inches.

3.All dimensions are ± 1/4 inch.

4.Discharge grilles are shipped loose for field installation.

5.Construction is roll formed aluminum frame and blades.

6.Standard finish is powder coated and will be the same color as the return grille.

7.Installation of grille on adjacent unit sides may require a duct extension to prevent air bypass around discharge grilles.

8.Mounting hardware included.

Fig. 3 — Double Deflection with Opposed Damper Aluminum Discharge Grille

5

Image 5
Contents General ContentsSafety Considerations Physical Data 50VS Unit InstallationDRAINa50-8295 Dimension a Water Coil Unit Connection50VSE,F 50VSG,H 50VSM,N10 x Dimensional DataA50-8291 Cabinet A50-829616 x 14 xA50-8297 A50-8298A50-8300 A50-8301 A50-8299Install Cabinet and Riser Framing Rough-In Detail A50-8331.epsSystem Expansion Loops A50-8332Minimum Temperature for LOW Antifreeze Percentages by VolumeType Temperature Protection 10 F 15 F 20 F 25 FRECIRCULATING† Water Quality GuidelinesCondition Closed Open Loop and Recirculating Well Chassis Electrical Data 50VS Unit Wire Field Power Supply ConnectionsA50-8352 Typical 50VS Unit Control WiringInstall Hose Kit Wire Field Control ConnectionsRecommended Wire Gage Low Voltage Thermostat Maximum RUN Unit toInstall Return Panel Install Chassis into the CabinetA50-8293 Hose Diameter Bend AllowancePRE-START-UP Install Supply GrilleA50-8302.eps Supply Grille Sizes and ArrangementsField Selectable Inputs DIP Switch Settings and OperationSystem Checkout START-UP Standard 24-vac Sequence of OperationOperating Limits Temperature Change Through Heat ExchangerWater Flow GPM Rise Drop Cooling F Heating F 20-26 10-17 Systems at 1.5 gpm per tonTroubleshooting ServiceWater Coil Maintenance LED1 LED2 LED3 LED4 TroubleshootingII. START-UP START-UP ChecklistCooling Cycle Analysis Heating Cycle Analysis