Carrier Air Conditioner specifications Temp Voltage Resistance Drop

Page 62

Table 33A — 10K Thermistor Temperatures (°F) vs Resistance/Voltage Drop

(For Thermistor T10)

TEMP

VOLTAGE

RESISTANCE

 

TEMP

VOLTAGE

RESISTANCE

 

TEMP

VOLTAGE

RESISTANCE

(F)

DROP (V)

(Ohms)

 

(F)

DROP (V)

(Ohms)

 

(F)

DROP (V)

(Ohms)

–25

4.758

196,453

 

61

2.994

14,925

 

147

0.890

2,166

–24

4.750

189,692

62

2.963

14,549

148

0.876

2,124

–23

4.741

183,300

63

2.932

14,180

149

0.862

2,083

–22

4.733

177,000

64

2.901

13,824

150

0.848

2,043

–21

4.724

171,079

65

2.870

13,478

151

0.835

2,003

–20

4.715

165,238

66

2.839

13,139

152

0.821

1,966

–19

4.705

159,717

67

2.808

12,814

153

0.808

1,928

–18

4.696

154,344

68

2.777

12,493

154

0.795

1,891

–17

4.686

149,194

69

2.746

12,187

155

0.782

1,855

–16

4.676

144,250

70

2.715

11,884

156

0.770

1,820

–15

4.665

139,443

71

2.684

11,593

157

0.758

1,786

–14

4.655

134,891

72

2.653

11,308

158

0.745

1,752

–13

4.644

130,402

73

2.622

11,031

159

0.733

1,719

–12

4.633

126,183

74

2.592

10,764

160

0.722

1,687

–11

4.621

122,018

75

2.561

10,501

161

0.710

1,656

–10

4.609

118,076

76

2.530

10,249

162

0.699

1,625

–9

4.597

114,236

77

2.500

10,000

163

0.687

1,594

–8

4.585

110,549

78

2.470

9,762

164

0.676

1,565

–7

4.572

107,006

79

2.439

9,526

165

0.666

1,536

–6

4.560

103,558

80

2.409

9,300

166

0.655

1,508

–5

4.546

100,287

81

2.379

9,078

167

0.645

1,480

–4

4.533

97,060

82

2.349

8,862

168

0.634

1,453

–3

4.519

94,020

83

2.319

8,653

169

0.624

1,426

–2

4.505

91,019

84

2.290

8,448

170

0.614

1,400

–1

4.490

88,171

85

2.260

8,251

171

0.604

1,375

0

4.476

85,396

86

2.231

8,056

172

0.595

1,350

1

4.461

82,729

87

2.202

7,869

173

0.585

1,326

2

4.445

80,162

88

2.173

7,685

174

0.576

1,302

3

4.429

77,662

89

2.144

7,507

175

0.567

1,278

4

4.413

75,286

90

2.115

7,333

176

0.558

1,255

5

4.397

72,940

91

2.087

7,165

177

0.549

1,233

6

4.380

70,727

92

2.059

6,999

178

0.540

1,211

7

4.363

68,542

93

2.030

6,838

179

0.532

1,190

8

4.346

66,465

94

2.003

6,683

180

0.523

1,169

9

4.328

64,439

95

1.975

6,530

181

0.515

1,148

10

4.310

62,491

96

1.948

6,383

182

0.507

1,128

11

4.292

60,612

97

1.921

6,238

183

0.499

1,108

12

4.273

58,781

98

1.894

6,098

184

0.491

1,089

13

4.254

57,039

99

1.867

5,961

185

0.483

1,070

14

4.235

55,319

100

1.841

5,827

186

0.476

1,052

15

4.215

53,693

101

1.815

5,698

187

0.468

1,033

16

4.195

52,086

102

1.789

5,571

188

0.461

1,016

17

4.174

50,557

103

1.763

5,449

189

0.454

998

18

4.153

49,065

104

1.738

5,327

190

0.447

981

19

4.132

47,627

105

1.713

5,210

191

0.440

964

20

4.111

46,240

106

1.688

5,095

192

0.433

947

21

4.089

44,888

107

1.663

4,984

193

0.426

931

22

4.067

43,598

108

1.639

4,876

194

0.419

915

23

4.044

42,324

109

1.615

4,769

195

0.413

900

24

4.021

41,118

110

1.591

4,666

196

0.407

885

25

3.998

39,926

111

1.567

4,564

197

0.400

870

26

3.975

38,790

112

1.544

4,467

198

0.394

855

27

3.951

37,681

113

1.521

4,370

199

0.388

841

28

3.927

36,610

114

1.498

4,277

200

0.382

827

29

3.903

35,577

115

1.475

4.185

201

0.376

814

30

3.878

34,569

116

1.453

4,096

202

0.370

800

31

3.853

33,606

117

1.431

4,008

203

0.365

787

32

3.828

32,654

118

1.409

3,923

204

0.359

774

33

3.802

31,752

119

1.387

3,840

205

0.354

762

34

3.776

30,860

120

1.366

3,759

206

0.349

749

35

3.750

30,009

121

1.345

3,681

207

0.343

737

36

3.723

29,177

122

1.324

3,603

208

0.338

725

37

3.697

28,373

123

1.304

3,529

209

0.333

714

38

3.670

27,597

124

1.284

3,455

210

0.328

702

39

3.654

26,838

125

1.264

3,383

211

0.323

691

40

3.615

26,113

126

1.244

3,313

212

0.318

680

41

3.587

25,396

127

1.225

3,244

213

0.314

670

42

3.559

24,715

128

1.206

3,178

214

0.309

659

43

3.531

24,042

129

1.187

3,112

215

0.305

649

44

3.503

23,399

130

1.168

3,049

216

0.300

639

45

3.474

22,770

131

1.150

2,986

217

0.296

629

46

3.445

22,161

132

1.132

2,926

218

0.292

620

47

3.416

21,573

133

1.114

2,866

219

0.288

610

48

3.387

20,998

134

1.096

2,809

220

0.284

601

49

3.357

20,447

135

1.079

2,752

221

0.279

592

50

3.328

19,903

136

1.062

2,697

222

0.275

583

51

3.298

19,386

137

1.045

2,643

223

0.272

574

52

3.268

18,874

138

1.028

2,590

224

0.268

566

53

3.238

18,384

139

1.012

2,539

225

0.264

557

54

3.208

17,904

140

0.996

2,488

 

 

 

 

55

3.178

17,441

141

0.980

2,439

 

 

 

 

56

3.147

16,991

142

0.965

2,391

 

 

 

 

57

3.117

16,552

143

0.949

2,343

 

 

 

 

58

3.086

16,131

144

0.934

2,297

 

 

 

 

59

3.056

15,714

145

0.919

2,253

 

 

 

 

60

3.025

15,317

 

146

0.905

2,209

 

 

 

 

62

Image 62
Contents Safety Considerations ContentsIntroduction ContentsGeneral Unit Sizes and Modular Combinations 30GUN,R Major System ComponentsUnit Sizes and Modular Combinations 30GTN,R Unit Nominal Section a Section B 30GTN,R Tons Unit 30GTN,RThermistor Designations Control Module CommunicationCarrier Comfort Network CCN Interface Status Switches Output RelayPage 24 V Control Schematic, Unit Sizes 24 V Control Schematic, Unit Sizes 080-110, 230B-315B CCN LEN Data Communication Port Main Base Board Operating Data 040-110 130-210Thermistor T3 and T4 Locations Compressor Thermistor Locations T7 and T8 Belden 8205 Regular Wiring Plenum Wiring Alpha 1895 AmericanManufacturer Columbia D6451 Manhattan M13402 M64430 Quabik 6130Compressor Protection Control System Module Sizes Stepper Motor 12 VDC CEPL130351 30GUN,R Part Load Data Percent Displacement, Standard UnitsDisplacement Compressors Approx110, 290B 255A 60 Hz390B 60 Hz 330A/B360B 50 Hz 390B 50 HzB1† A1,B1 A1†,A2,B1 A1*,B1†,B2 Unloaded compressor Two unloaders, both unloaded 170, 270A 190, 290A, 360A/BA1*,B1*,B2 Required Hardware for Additional Unloaders 150-210Head Pressure Control PumpoutPower FAN Arrangement FAN Relay Normal ControlService Test See Both main power Scrolling Marquee DisplayModes GEN.O TestStrt Run Status Mode and Sub-Mode DirectorySUB-MODE Keypad Range Item Expansion Comment Entry View VersOuts Service Test Mode and Sub-Mode DirectorySUB-MODE Keypad Range Item Expansion Comment Entry Test Set Point Mode and Sub-Mode Directory Temperature Mode and Sub-Mode DirectoryPressure Mode and Sub-Mode Directory SUB-MODE Keypad Range Item Expansion Comment Entry GEN.I Inputs Mode and Sub-Mode DirectoryReading and Changing Chilled Fluid Set Point CrctSUB-MODE Keypad Range Item Expansion Comment Entry GEN.O Outputs Mode and Sub-Mode DirectoryConfiguration Mode and Sub-Mode Directory CCN OPT1OPT2 EMM240 RsetExample of Temperature Reset Return Fluid Configuration SUB-MODE Keypad Display Item Expansion Comment Entry RsetSUB-MODE Keypad Entry Display Item Expansion Comment Rset Example of Configuring Dual Chiller Control Master ChillerExample of Configuring Dual Chiller Control Slave Chiller SUB-MODE Keypad Display Item Expansion Comment Entry OPT2 Example of Compressor Lead/Lag ConfigurationTime Clock Mode and Sub-Mode Directory SUB-MODE Keypad Entry Item Expansion Comment Range TimeSetting an Occupied Time Schedule Operating Mode and Sub-Mode DirectoryMode no Item Expansion Description Operating ModesAlarms Mode and Sub-Mode Directory Example of Reading and Clearing AlarmsConfiguration Configuring Temperature ResetMode Keypad SUB-MODE Entry ExpansionRED LED Entry Expansion Configuration Configuring Demand Limit DLS2Troubleshooting To 20 mA Demand LimitingPage Alarm and Alert Codes T051FSM By Control Method Cause Code Alert GENERATED?EWT LCWT170 T153T155 T173T205 T203T204 T206Oil Charge ServiceElectronic Components Compressor OIL RequiredCooler Thermistor Locations Plugs Components for Part Number PluggingCondenser Coils Cooler Head Bolt Tightening Sequence Typical Tube SheetCondenser Fan Adjustment Hz Low Noise Fan Option Units Dimension FAN TypePrinted Circuit Board Connector Refrigerant Feed Components Each circuit hasThermistors Temperature Sensors Drop a 5K Thermistor Temperature F vs Resistance/VoltageDrop B 5K Thermistor Temperature C vs Resistance/Voltage Temp Voltage Resistance Drop 200,510 30GTN,R Units Pressure Switch Settings Psig kPaSwitch Cutout CUT-IN 30GUN,R UnitsPRE-START-UP System CheckMaximum Ambient Temperature 125 Temperature Limits for Standard UnitsTemperature START-UP and OperationNominal and Minimum Cooler Fluid Flow Rates Field WiringRefrigerant Circuit Hgbps ALMCWP Energy Management Module EMM Wiring Compressor Expansion Board CXB Accessory Wiring Description Status Default Units Point Unit Configuration SettingsOPTIONS1 Options Configuration Description Status Default PointAppendix a CCN Tables OPTIONS2 Options ConfigurationAlarmdef Alarm Definition Table Resetcon Temperature Reset and Demand Limit Brodefs Broadcast POC Definition TableCircadio Circuit a Discrete Parameters Aunit General Unit ParametersCircaan Circuit a Analog Parameters Description Status Units Point ForceableCircban Circuit B Analog Parameters Circbdio Circuit B Discrete ParametersOptions Unit Parameters Strthour Description Status Units PointDescription Status Units Point Defaults CurrmodsDescription Status Point CSM/FSM Equipment Table Type 621H, BlockLine Description Point Appendix B Fluid Drop Pressure Curves Cooler Fluid Pressure Drop Curves 30GUN,GUR040-110Cooler Pressure Drop KEY Appendix B Fluid Drop Pressure CurvesCooler Fluid Pressure Drop Curves 30GUN,GUR130-210 Appendix B Fluid Drop Pressure Curves Cooler Fluid Pressure Drop Curves 30GUN,GUR230B-315B Cooler Fluid Pressure Drop Curves 30GTN,GTR040-110 Cooler Fluid Pressure Drop Curves 30GTN,GTR130-210 Appendix B Fluid Drop Pressure Curves Module B 30GTN,GTR230,245 Module B 30GTN,GTR255,290,315 Service Training Call for Free CatalogEquipment Chiller Model no START-UP Checklist for Comfortlink Chiller SystemsRemove and use for job file Preliminary Information Preliminary Equipment Check Check box if complete System Fluid Volume in Loop Type System UnitStart-UpUnit Start-Up Ccnb Description Status Units Value CtrlCcna BaudSlct Heating Cooling Setpoint Select CND.P RMT.A All Units

Air Conditioner specifications

Carrier Air Conditioners have long been synonymous with reliability and innovation in climate control. Founded by Willis Carrier, the inventor of modern air conditioning, the brand has continuously set industry standards through state-of-the-art technologies and features designed to enhance indoor comfort.

One of the standout features of Carrier air conditioners is their energy efficiency. Many models are equipped with advanced inverter technology, allowing the compressor to adjust its speed based on the cooling demand. This results in decreased energy consumption, which not only reduces utility bills but also lessens the environmental impact. Recognizing the importance of sustainable practices, Carrier has integrated eco-friendly refrigerants into their systems, further promoting energy-efficient operations.

Carrier also emphasizes user comfort through its variable speed systems. These systems maintain consistent temperatures while minimizing temperature fluctuations, ensuring an even distribution of cool air throughout the home. Additionally, many Carrier models come with advanced air filtration systems, designed to capture allergens, dust, and other particulates, thereby improving indoor air quality.

The smart technology featured in Carrier air conditioners plays a key role in modern convenience. Many units are compatible with smart home systems, allowing users to control settings remotely via smartphones or voice-activated devices. With features like programmable thermostats, users can easily set cooling schedules to match their lifestyle, ensuring comfort while maximizing energy savings.

Durability and noise reduction are also central to the Carrier brand. Many models are designed with sound-dampening features, making them some of the quietest units on the market. This is particularly advantageous for residential use, where noise can disrupt daily activities and sleep.

In terms of design, Carrier air conditioners come in various styles and capacities to suit a wide range of spaces, from compact apartment units to large central systems for sprawling homes. Their extensive warranty and service offerings further reinforce Carrier’s commitment to customer satisfaction.

In conclusion, Carrier air conditioners represent a perfect blend of cutting-edge technology, energy efficiency, and user comfort. Their emphasis on sustainability and smart features positions them as a leading choice for homeowners seeking reliable and innovative climate control solutions. Whether for cooling a small room or an entire house, Carrier remains a trusted name in air conditioning.