location is ideal for the maintenance technician, and five access panels, easily removed, provide quick and convenient access to all components when needed. As an added plus, all required service/ maintenance access can be from one side allowing the unit to be located against a wall or ceiling plenum obstruc- tion, an obvious
Carrier quality and reliability
The Carrier 50AH ROOMTOP® units have much to offer the cost- and
Scroll compressor technology
Scroll compressors are designed for high efficiency and are internally spring mounted to minimize vibration noise. Each compressor is hermetically sealed against contamination to promote longer life and dependable operation. Scroll compressors are standard on all units.
Table of contents
Page
Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,2
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ARI Capacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,10
Typical Wiring Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11,12
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14,15
Quality Assurance
I |
| ® |
|
|
|
| 5 |
O |
|
|
|
|
|
| |
|
|
|
|
|
| 2 | |
S |
|
|
|
|
| 3 |
|
9 |
|
|
|
| 2 |
| |
0 |
|
| A |
|
| ||
| 0 | 1:2 | 000 | # |
|
|
|
|
|
|
|
|
|
Model number nomenclature
50AH – 048 – M – 5 4 1 XX
Model Designation –
50AH Horizontal,
Indoor
Cooling Unit
Nominal Tons |
|
| |||
024 | – | 2 | 048 | – | 4 |
036 | – | 3 | 060 | – | 5 |
Indoor Fan Motor
– – Standard Motor
M – 1.5 hp Optional Motor
FIOP*
Packaging
1– Domestic
2– Export
Design Revision
Voltage | 6 – | |
3 | – | |
5 | – |
|
*FIOP —
ARI* capacity ratings
UNIT | TOTAL | NET TOTAL | NOMINAL | EER | SEER | SEER | SOUND RATING | ||
50AH | kW | COOLING CAP. (Btuh) | CFM | (with TDR) | (dB) | ||||
|
|
| |||||||
024 | 2.56 | 24,800 | 800 | — | — | 10.50† | 78 | ||
036 |
|
|
| — | 10.00 | 10.00 |
| ||
4.3 | 36,000 | 1200 | 8.40 | — | — | 82 | |||
|
|
|
| 8.40 | — | — |
| ||
048 |
|
|
| — | — | 10.00† |
| ||
5.63 | 49,500 | 1600 | 8.80 | — | — | 82 | |||
|
|
|
| 8.80 | — | — |
| ||
060 |
|
|
| — | 9.70 | 10.00 |
| ||
6.9 | 58,500 | 2000 | 8.50 | — | — | 82 | |||
|
|
|
| 8.50 | — | — |
|
dB | — | LEGEND |
Decibels | ||
EER | — | Energy Efficiency Ratio |
SEER — | Seasonal Energy Efficiency Ratio | |
TDR | — |
NOTES:
1.Ratings are at zero condenser air static and rated in accordance with ARI Standard 210.
NET CAPACITY (Btuh)
2. EER =
TOTAL WATTS
2