Field-installed accessories

Thermostat and subbase — Attractive wall-mounted 24-v accessory provides precise temperature control. Automatic and Manual changeover models available. A thermostat subbase is available that works with Cycle- LOC™ circuitry. If a safety device trips, compressor locks out and subbase warning light (LK OUT) alerts occupant.

Three models available: One stage cool/two stage heat; two stage cool/two stage heat; one stage cool/one stage heat.

Time Guard® II circuit (standard on single-phase units) — Time Guard II device prevents short cycling of compressor if thermostat is rapidly changed; automatically prevents compressor from restarting for 5 minutes after shutdown.

Electric heaters — A wide range of models is available from 5 to 30 kW, 208-, 240- and 480-v, single- and 3-ph units. The heaters mount easily on 50AH discharge open- ing. The heater control box is accessible from the bottom of heater.

Condensate pump — The condensate pump is used when the distance and slope to the nearest drain is far enough to prevent the natural drainage of unit. The pump is mounted remotely from the unit and includes a signal light (field-installed) which illuminates when the reservoir rises beyond a certain level. The unit automatically shuts down when this reservoir level is achieved.

Head pressure control damper — This accessory is duct mounted and allows unit to mechanically cool down to 0° F.

Damper dimensions fit 024, 036 sizes.

NOTE: For use with 048 and 060 size units, ductwork from unit to damper must be reduced in size to fit damper dimensions.

Vibration isolators — Package of four isolators used for dampening any unit vibration so that vibrating sounds are not transmitted to building structure. Isolators are spring, ceiling type.

 

88EN ELECTRIC HEAT MODULE

HEAD PRESSURE CONTROL DAMPER (in.)

 

 

 

ACCESSORY

 

 

 

 

DIMENSIONS (in.)

 

 

 

 

 

 

 

 

 

 

 

UNIT

A

B

C

D

DUCT

 

 

50AH

OPENING

 

 

 

 

 

 

 

 

024,036

131/2

16

21/2

81/2

71/8 x 14

 

 

048,060

24

213/4

3

19

71/8 x 207/8

 

 

 

 

 

 

 

 

 

4

Image 4
Contents Features/Benefits Product DataModel number nomenclature Table of contentsARI* capacity ratings Operating Weight Distribution Center of Gravity DimensionsPhysical data UnitField-installed accessories Accessory88EN Electric Heat Module Unit DuctBase unit dimensions Unit Component LocationsSelection procedure with example Performance dataGross Cooling Capacities SHCUnit Size 50AH CFM Evaporator FAN PerformanceESP Condenser FAN Performance Belt Drive Evaporator FAN PerformanceUnit Cond Unit Voltage Range Compressor FAN Motors Power Supply ControlsElectrical data Electric Heater Unit MIN Unit CFM Unit 88ENElectric Heater Data Electric Heater Used withBranch Circuit Unit 88EN Unit 50AH MCATypical wiring schematic CLO LOROUTDOOR-AIR Temperature Operating Limits F Typical piping and wiringApplication data Guide specifications Indoor Packaged UnitPage Carrier Corporation Syracuse, New York 204