Cateye MODEL EC-1600 External computer control via an RS232C Terminal, Transmission Format

Models: MODEL EC-1600

1 32
Download 32 pages 41.73 Kb
Page 27
Image 27

External computer control via an RS232C terminal

External computer control via an RS232C

terminal

If you connect the optional "RS232C Communication Kit," the Ergo- ciser™ can communicate with an external computer.

Specifically, you can write a program with an external computer in Basic or in another computer language, and operate the Ergociser™ EC-1600 according to the written procedure. Any instructions input by the buttons on the EC-1600 control unit can be input from the ex- ternal computer, and the EC-1600 sends data to an external computer every second. Since command signals are in ASCII character code, any computer that generates these codes can be used, receiving and transmitting via the RS232C terminal.

Transmission Format

Communication speed (baud rate)

2400

Data bit length

8 bit

Stop bit

1 bit

Parity check

none

XON / XOFF control

none

SI/SO control

none

Contents of Data Transmission from the EC-1600

The EC-1600 outputs display data in character code, continuously when you set exercise conditions and once per second when you are exercising. Since the contents of the LCD differs according to setting exercise conditions and during exercise, the content of data output also differs.

1) Setting Exercise Conditions

Address

Data

Function

 

1

A code

Hexadecimal 41H

2

3 digit numeric

Set wattage (Isopower Training)

5

1 digit numeric

Exercise pattern (Interval Training)

6

3 digit numeric

Target pulse rate (Auto Training)

9

1 digit numeric

Sex (male:"1", female:"0")

10

1 digit numeric

Exercise pattern (Hill Profile Training)

11

2 digit numeric

Set torque x 10

 

13

3 digit numeric

Weight (Aerobic Power Measurement)

16

2 digit numeric

Target time (minutes)

18

3 digit numeric

Pulse limit value

 

21

2 digit numeric

Age

 

23

CR code

Hexadecimal 0DH

2) During Exercise

 

 

 

 

 

 

Address

Data

Function

 

1

B code

Hexadecimal 42H

2

4 digit numeric

Elapsed time

2 digits = "minute"

 

 

 

2 digits = "second"

6

4 digit numeric

Calorie consumption

10

3 digit numeric

Wattage

 

13

2 digit numeric

Pedal torque x 10

15

3 digit numeric

Pulse rate

18

3 digit numeric

Pedal cadence

21

1 digit numeric

Aerobic power measurement result: PFL

22

2 digit numeric

Aerobic power measurement result: MOU

24

3 digit numeric

Aerobic power measurement result: PWC max.

27

3 digit numeric

Set wattage (Isopower training)

30

2 digit numeric

Lowest 2 digits of addition value of data address 2 ~ 29

32

CR code

Hexadecimal 0DH

Note: "0" is displayed in each digit for the 3 types of aerobic power measurement results, until the program is completed.

Externally Controlling the EC-1600

1) During Setting Exercise Conditions

When exercise conditions are being set, you can send data in a "char- acter code + numeric code + CR code" format (shown in example below) from an external computer, setting your exercise conditions.

Example)

"K6CR" : Selects Auto Training

 

 

Character Code

Function

A

Age (up to 2 digits)

BPulse limit value (up to 3 digits)

CTarget time (up to 2 digits)

D

Weight (up to 3 digits)

ESet torque x 10 (2 digits)

FExercise pattern (Hill Profile Training)

GSex (male: "1", female: "0")

HTarget pulse rate (up to 3 digits)

ISet wattage (up to 3 digits)

JExercise pattern (Interval Training)

KExercise program

1:Aerobic Power Measurement

2:Manual Training

3:Hill Profile Training

4:Interval Training

5:Isopower Training

6:Auto Training

LReset torque during exercise x 10 (2 digits)

2)During Exercise

By using the following character codes for button operation, you can externally control the program during exercise.

Example) Sending "i CR" during Manual Training

→ increases pedal resistance (torque) 0.1 kg·m

Character Code

Function

r

RESET button

g

ADV button

i

+ 1 button

d

– 1 button

See the instruction manual for the optional "RS232C Communication

Kit" for details.

46

47

Page 27
Image 27
Cateye MODEL EC-1600 operating instructions External computer control via an RS232C Terminal, Transmission Format