Cateye MODEL EC-1600 Automatic training, Select the Automatic Training Program Input Conditions

Models: MODEL EC-1600

1 32
Download 32 pages 41.73 Kb
Page 19
Image 19

Automatic training

1 Select the Automatic

Training Program

2 Input Conditions

PLL

 

AGE

TM

min:sec

 

AUTO

TPL

bpm

 

For program selection see the Starting up section page 18.

Input age, pulse limit, exercise time and the target pulse rate. The initial display before input is as in the drawing, with the nu- meric for age blinking.

Initial Value

Setting Range

Age

40

10~

99

Pulse Limit

160 bpm

80~ 200 bpm

Exercise Time

20 min

0~

99 min

 

 

 

Target Pulse Rate

120 bpm

60~ 180 bpm

• The pitch sound to adjust your cadence at 60 rpm (rings every

half second) is set "OFF".

Exercise Maintaining the

5 Target Pulse Rate

rpm

TM

min:sec

 

AUTO

watt

kg•m

kg•m

TIME

• After the WARM symbol has gone out, during exercise every time the pulse rate digresses ± 3 bpm from the target, the load changes 0.1 kg·m, keeping your pulse rate close to the target pulse rate.

Note: When the pulse rate is "0" (when the earlobe sensor is removed) or when the pedal cadence is "0" (when not exer- cising) the pedal resistance does not change.

Remark 1: You can increase or decrease the pedal resistance

by pressing the buttons.

Remark 2: The graphic section will display the torque pattern for maximum 16 minutes. At the end of 16 minutes period, torque pattern once disappear and the actual torque at that moment will be displayed flashing at the left end of the section.

TIME

3 Start Program

4 Start / Warm Up

• There is no graphic display yet in the LCD.

• You can increase or decrease the blinking numeric by pressing

the

 

 

 

 

 

buttons.

 

 

 

 

 

• Press the

MODE button to change the blinking numeric.

• After setting your conditions, adapt the earlobe pulse sensor

and depress ADV button to start program.

• After printing out the conditions, the LCD changes as in the

drawing.

 

 

6 Finish Exercise

Cool Down

rpm

TM

min:sec

 

AUTO

watt

kg•m

kg•m

COOL

TIME

• The buzzer sounds at the specified time. If you press the ADV button, the program enters a 5 minute cool down phase and the COOL symbol lights up, then the pedal resistance becomes the minimum of 0.5 kg·m.

Note: Even if the buzzer sounds the program does not enter the cool down phase unless you press the ADV button.

The LCD still displays the same exercise data.

rpm

TMmin:sec

• The initial workload (pedal torque) is indicated in blinking dot

in the graphic section of the LCD. One dot along the horizontal

axis indicates 30 seconds, and one along the vertical axis 0.5

kg·m. At every 30 seconds, the row of dots will increase by one

towards the right of the graphic section, with the last row blink-

7 End Program

If the 5 minute cool down phase has elapsed or if you press the

ADV button, the buzzer sounds and the program ends. The

calorie consumption is printed out, and the LCD returns to the initial screen.

• If you are completely finishing the exercise, be sure to switch off

the main body.

watt

AUTO

kg•m

kg•m

WARM

TIME

ing.

• The pedal resistance increases gradually, so that the pulse rate

goes up toward the target pulse rate.

• The WARM symbol remains until your pulse rate gets close to

the target pulse rate.

Sample print out

• Shows that the Auto training program has been preformed.

Target pulse rate

• Upper limit pulse rate

• Calorie consumption

30

31

Page 19
Image 19
Cateye MODEL EC-1600 Automatic training, Select the Automatic Training Program Input Conditions, Finish Exercise Cool Down