WARNING

INSTRUCTIONS

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

DThis equipment is for professional use only.

DRead all instruction manuals, tags, and labels before operating the equipment.

DUse the equipment only for its intended purpose. If you are not sure, call your distributor.

DDo not alter or modify this equipment. Use only genuine Graco parts.

DCheck equipment daily. Repair or replace worn or damaged parts immediately.

DDo not exceed the maximum working pressure of the lowest rated system component. Refer to the Technical Data on page 27 for the maximum working pressure of this equipment.

DUse fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer's warnings.

DDo not use 1,1,1±trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.

DDo not use hoses to pull equipment.

DRoute hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82_C (180_F) or below ±40_C (±40_F).

DDo not lift pressurized equipment.

DComply with all applicable local, state, and national fire, electrical, and safety regulations.

NOTE: This is an example of the DANGER label on your sprayer. This label is available in other languages, free of charge. See page 27 to order.

FIRE AND

SKIN INJECTION

EXPLOSION HAZARD

HAZARD

Spray painting, flushing or cleaning equipment with flammable liquids in

Liquids can be injected into the body by high pressure airless spray or

confined areas can result in fire or explosion.

leaks ± especially hose leaks.

Use outdoors or in extremely well ventilated areas. Ground equipment,

Keep body clear of the nozzle. Never stop leaks with any part of the

hoses, containers and objects being sprayed.

body. Drain all pressure before removing parts.Avoid accidental trigger-

Avoid all ignition sources such as static electricity from plastic drop

ing of gun by always setting safety latch when not spraying.

 

cloths, open flames such as pilot lights, hot objects such as cigarettes,

Never spray without a tip guard.

arcs from connecting or disconnecting power cords or turning light

In case of accidental skin injection, seek immediate

switches on and off.

ªSurgical reatmentºT.

Failure to follow this warning can result in death or serious injury.

Failure to follow this warning can result in amputation or serious injury.

 

READ AND UNDERSTAND ALL LABELS AND INSTRUCTION MANUALS BEFORE USE

4￿ 3￿￿￿￿3￿

Image 4
Contents This manual contains important warnings and information 307±830Read and Keep for Reference Table of Contents SymbolsInjection Hazard Equipment Misuse Hazard Fire Skin Injection Explosion HazardSetup 114 Startup Injection HazardFire and Explosion Hazard Prime the pumpMaintenance Flushing Right Application MethodsWrong Pressure Relief Procedure TroubleshootingProblem Cause Solution Sion Hazard on Motor Brush Replacement Displacement Pump Reinstalling the pump SeeConnecting Rod and Bearing Housing Detail aDrive Housing Motor Partial Wiring Diagram Conduit Seal DetailAdjust the pressure control. See Pressure Control102 101 130 Pressure Control Adjustment Maximum Working Pressure  Part No ±858 Pressure Control Assembly Parts ± Pressure ControlDetail B Parts ± Upright SprayerSee Detail a Model 220±856, Series D Model 231±590, Series aPage Technical Data AccessoriesDisplacement Pump Repair 222±588 Motor Brush Replacement Kit, 220±853Additional Warranty Coverage Graco WarrantyFor Graco Canada Customers