Component Identification

Component Identification

 

E

X

 

 

 

 

 

B

M

 

 

 

 

 

 

G

 

A

 

R

Mounting Components for

 

 

 

 

 

Pump Package

 

 

H

 

 

 

 

U

 

 

 

 

N

 

 

 

 

F

 

P

 

 

 

 

 

 

A

V

 

 

 

T

 

 

B

 

 

 

 

 

 

 

 

J

 

S

C

 

D

 

 

 

 

 

 

 

D

D

 

 

 

 

 

 

 

Y

 

 

 

K

 

 

 

W

L

 

 

 

 

 

 

 

 

r_571101_3a0420a_1a-2

 

FIG. 1: XP70 Sprayer with optional accessories

Key:

AAir Motor Supply Hose

BMain Air Controls; see page 13

CAir Inlet - 3/4 Npsm(F)

DHigh Pressure Fluid Pump

EAir Motor

FFluid Heater (optional)

GSolvent Flush Pump (optional); see page 14

HSolvent Flush Pump Air Controls; see page 14

J7 Gallon Hoppers (optional)

KCart

LBrake

MHandle (lift to release)

NFluid Control Assembly; see page 13 P Tie Rods

R Motor Adapter Plate

S Adjustable Packing Nuts with Wet Cups T Yoke With Rod Bearings

U Recirculation Lines V Yoke Position Nut

W Static Mixer Tubes with Replacement Plastic Elements X Motor Position Indicator

Y Over Pressure Rupture Disc; only 38cc, 48cc, and 58cc pumps

12

3A0420H

Image 12
Contents XP70 Plural-Component Sprayer Contents Related Manuals Manual DescriptionFire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Changing Materials B Component DesignationsMachine Left Machine Right Market Equipment Designations Overview UsageOver Pressure Protection Initial System Setup Models Cart-Mounted XP70 SprayersBare Proportioning Pump Packages Component Identification Mounting Components forFluid Control Assembly Main Air ControlsSolvent Flush Pump Kit 262393 optional Included with optional solvent flush pump kit KeyFluid Line Accessories Flush Before Using EquipmentOptional Accessories Air LineSetup LocationGrounding Wire Sprayers with Explosion-Proof Heaters Hazardous location sprayers onlyAir Motor Position Position Air MotorConnect Air Supply Connect Fluid Hose Bundles Remote OnlyConnect Static Mixers, Gun, and Hoses Pressure Relief Procedure Relieve a and B Fluid PressurePrime Empty Sprayer Prime a and B FluidsPrime Solvent Flush Pump Recirculate or Re-Prime After a Pump Runs Dry Without HeatWith Heat Heat FluidSpray Side Mix Manifold Restriction Follow Pressure Relief Procedure, Flush Mixed MaterialFlush Mix Manifold, Hose, and Spray Gun Use Optional Solvent PumpProcedure GuidelinesShutdown ParkSystem Verification Maintenance Troubleshooting Problem Cause SolutionPump Troubleshooting Pump Assembly Remove Pump AssemblyRemove Displacement Pump RepairReplace Air Control Assembly Air ControlsRemove Air Motor Replace Air Filter ElementAir Control Assembly Air FlowMix Manifold Assembly Fluid Circulation ManifoldReplace Drain Valve Cartridges Repair Hoppers Solvent PumpService and Repair Optional Fluid HeatersReplace Parts Cart-Mounted XP70 Sprayer49 a 49 B 27, 28 32 27 Common Parts Part Description QtyParts Varying by Model with Hoppers Parts Varying by Model with No HoppersBare Proportioning Pump Package 122 106 105 135 117 108 101 138 139 140Varying Parts Ratio Description571100 571150 571200 571250 571300 571400 Qty 202 211 205 209 210 Ref. No. Part No. Description QtyFluid Manifold Part No. Description QtyRecommended Spare Parts Pump Repair KitsPump Filter O-rings packs Pump Performance Charts Calculate Fluid Outlet PressureCalculate Pump Air Flow/Consumption 11 or 21 Mix RatioPump Performance Charts Mix Ratio31 Mix Ratio Bar MPaPsig PressureAccessories and Kits Acceptable For Use in Explosive AtmospheresNot Approved For Explosive Atmospheres Technical Data Psi MPa, bar Psi MPa, psi Gpm ltr/minDimensions Floor Mounting Dimensions Top VIewTop VIew Side VIewBare Proportioner Mounting Hole Dimensions Graco Standard Warranty Graco Information