Graco XP70 important safety instructions Technical Data, Psi MPa, bar Psi MPa, psi Gpm ltr/min

Page 53

 

 

 

 

 

 

 

Technical Data

Technical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combined

Maximum Air

Maximum Fluid

Flow Rate at

Volume

Pressure

“A” Side

“B” Side

Fluid Output

Working Pressure

Working Pressure

40 cycles/min

Mix Ratio

Ratio

Pump

Pump

cc/cycle

psi (MPa, bar)

psi (MPa, psi)

gpm (ltr/min)

 

 

 

 

 

 

 

 

1:1

76:1

Xtreme 85

Xtreme 85

173

95 (0.6, 6.5)

7250 (50, 500)

1.8 (6.9)

1.5:1

91:1

Xtreme 85

Xtreme 58

144

80 (0.5, 5.5)

7250 (50, 500)

1.5 (5.7)

2:1

76:1

Xtreme 115

Xtreme 58

174

95 (0.6, 6.5)

7250 (50, 500)

1.8 (6.9)

2.5:1

65:1

Xtreme 145

Xtreme 58

203

100 (0.7, 7)

6500, 45, 448)

2.1 (8.1)

3:1

68:1

Xtreme 145

Xtreme 48

193

100 (0.7, 7)

6800, 47, 469)

2.0 (7.7)

4:1

73:1

Xtreme 145

Xtreme 36

181

100 (0.7, 7)

7250 (50, 500)

1.9 (7.2)

Air inlet size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maximum air pressure supply to the sprayer . . . . . . . . . . . . .

Filtration:

Air inlet filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

XP70 pump outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

XTR7 Spray Gun. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fluid pump inlets without hoppers. . . . . . . . . . . . . . . . . . . . . .

Fluid gauge manifold outlets . . . . . . . . . . . . . . . . . . . . . . . . . .

Fluid mix manifold inlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Mix manifold material outlet . . . . . . . . . . . . . . . . . . . . . . . . . .

Maximum feed pressure from remote source . . . . . . . . . . . . .

Fluid Viscosity Range:

Gravity feed with 7 gallon (26 liter) hoppers . . . . . . . . . . . .

Pressure feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Environmental Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Hazardous Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ambient Temperature Range:

Operating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maximum Fluid Temperature . . . . . . . . . . . . . . . . . . . . . . .

Sound pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sound power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wetted materials:

Housings and manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . .

Miscellaneous parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pump packings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Flush pump suction tube. . . . . . . . . . . . . . . . . . . . . . . . . . .

Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Weight:

Full System with heaters, solvent flush pump, and hoppers Bare system with no heaters, solvent flush pump, or hoppers

Maximum Storage Time:

Maximum Lifetime:

Power Efficiency Factor:

3/4 npsm(f)

75 cfm at 100 psi inlet/gpm

0.56cu meter/min at 7 bar/liter/min 175 psi (1 MPa, 12 bar)

40-micron filter/separator included

30mesh

60mesh

1-1/4 in. npsm(m) 1/2 in. npt(f)

3/8 in. npt(m) ball valves 1/2 in. npt(f)

250psi (1.7 MPa, 17 bar)

200 to 20,000 cps (pourable)

Any viscosity that will not require feed pressure more than 15% of outlet pressure

Indoor/outdoor EX II 2 G c IIA T2

40-130°F (4-54°C)

30-160°F (-1-71°C) 160°F (71°C)

86 dBA at 100 psi (0.7 MPa, 7 bar)

98 dBA at 100 psi (0.7 MPa, 7 bar)

Carbon steel with electroless nickel plating

Plated carbon steel, stainless steels, carbide, acetal, UHM- WPE, nylon, PTFE solvent resistant plastics

Carbon filled PTFE Aluminum

Nylon core

575 lbs (260 kg)

425 lbs (192 kg)

5 years (To maintain original performance, replace soft seals after 5 years of inactivity.)

Indefinite with recommended maintenance and periodic rebuilds for critical parts.

75 cu. ft compressed air/1 gallon sprayed material at 100 psi

0.56m3 compressed air /1 liter sprayed material at 0.7 MPa (7 bar)

3A0420H

53

Image 53
Contents XP70 Plural-Component Sprayer Contents Manual Description Related ManualsFire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Machine Left Machine Right Market Equipment Designations Changing MaterialsB Component Designations Over Pressure Protection OverviewUsage Initial System Setup Bare Proportioning Pump Packages ModelsCart-Mounted XP70 Sprayers Mounting Components for Component IdentificationMain Air Controls Fluid Control AssemblyIncluded with optional solvent flush pump kit Key Solvent Flush Pump Kit 262393 optionalFlush Before Using Equipment Fluid Line AccessoriesOptional Accessories Air LineGrounding SetupLocation Hazardous location sprayers only Wire Sprayers with Explosion-Proof HeatersPosition Air Motor Air Motor PositionConnect Static Mixers, Gun, and Hoses Connect Air SupplyConnect Fluid Hose Bundles Remote Only Relieve a and B Fluid Pressure Pressure Relief ProcedurePrime a and B Fluids Prime Empty SprayerPrime Solvent Flush Pump Without Heat Recirculate or Re-Prime After a Pump Runs DryWith Heat Heat FluidSpray Side Mix Manifold Restriction Flush Mixed Material Follow Pressure Relief Procedure,Flush Mix Manifold, Hose, and Spray Gun Use Optional Solvent PumpGuidelines ProcedurePark ShutdownSystem Verification Maintenance Problem Cause Solution TroubleshootingPump Troubleshooting Remove Pump Assembly Pump AssemblyRemove Displacement Pump RepairAir Controls Replace Air Control AssemblyRemove Air Motor Replace Air Filter ElementAir Flow Air Control AssemblyReplace Drain Valve Cartridges Mix Manifold AssemblyFluid Circulation Manifold Repair Solvent Pump HoppersReplace Service and RepairOptional Fluid Heaters Cart-Mounted XP70 Sprayer Parts49 a 49 B 27, 28 32 27 Part Description Qty Common PartsParts Varying by Model with No Hoppers Parts Varying by Model with Hoppers122 106 105 135 117 108 101 138 139 140 Bare Proportioning Pump Package571100 571150 571200 571250 571300 571400 Qty Varying PartsRatio Description Ref. No. Part No. Description Qty 202 211 205 209 210Part No. Description Qty Fluid ManifoldPump Filter O-rings packs Recommended Spare PartsPump Repair Kits Calculate Fluid Outlet Pressure Pump Performance ChartsCalculate Pump Air Flow/Consumption 11 or 21 Mix Ratio31 Mix Ratio Pump Performance ChartsMix Ratio MPa BarPsig PressureNot Approved For Explosive Atmospheres Accessories and KitsAcceptable For Use in Explosive Atmospheres Psi MPa, bar Psi MPa, psi Gpm ltr/min Technical DataFloor Mounting Dimensions Top VIew DimensionsTop VIew Side VIewBare Proportioner Mounting Hole Dimensions Graco Information Graco Standard Warranty