Setup
Air Motor Position
The air motor position must be set for the mix ratio of the machine, which is defined by which two pumps are mounted.
1.Verify that the correct pumps are mounted for your mix ratio by volume. See chart in Bare Proportion- ing Pump Packages on page 11.
2.Verify that the motor position is adjusted correctly for that mix ratio.
indicator line
indicator line
r_258914_3a0420a_10b
FIG. 6: Ratio indicators
Position Air Motor
There are specific positions for each fixed ratio setting. To adjust the position of the air motor:
1.Loosen the eight fasteners and remove the two pump guards.
fastener
pump guard
fastener
pump guard
2.Place wrench on adapter rod (104).
3.Use tool (70) to loosen the serrated yoke nut (V) above the yoke (T).
104
V
T
4. Loosen the three nuts (P2) below the motor tie rods.
E
piston rod
V
P2
T
r_258914_3a0420a_5a
5.Grab the piston rod and slide the position of the motor (E) until the indicator lines are aligned with your ratio. See FIG. 6.
NOTICE
Do not hit tie rods (P) with a steel hammer. Damage to the air motor base may result.
6.Tighten the three nuts (P2) and yoke nut (V). Use tool (70) to tighten the yoke nut.
7.Install the pump guards.
18 | 3A0420H |