Graco 332709B important safety instructions Emix, EQU0, EQU1

Page 15

 

 

 

 

 

Troubleshooting

 

 

 

 

 

 

Code

Type

Description

Problem

Cause

Solution

 

 

 

 

 

 

EF0#

Alarm

Timeout

Pump tried but was not

Pump dose valves did

Verify air pressure

 

 

Startup

able to move to the

not actuate.

to solenoid valves.

 

 

Pump #

home position within

 

Verify the valves are

 

 

 

a specified amount of

 

actuating.

 

 

 

time.

Motor could not drive

Verify motor is driving

 

 

 

 

 

 

 

 

pumps and linear

the pump.

 

 

 

 

actuator.

 

 

 

 

 

Pump stroke length

Verify correct

 

 

 

 

is shortened by

assembly of linear

 

 

 

 

mechanical system

actuator and pump

 

 

 

 

tolerance.

piston rods. See pump

 

 

 

 

 

manual.

EF1#

Alarm

Timeout

Pump tried but was not

Pump dose valves did

Visually inspect valves

 

 

Shutdown

able to move to the

not actuate.

to ensure they are

 

 

Pump #

park position within a

 

operating properly;

 

 

 

specified amount of

 

verify they have air

 

 

 

time.

 

pressure above 85 psi

 

 

 

 

 

(0.6 MPa, 6.0 bar).

 

 

 

 

Pump is filled with

Observe motor and

 

 

 

 

thick paint and could

drive assembly to

 

 

 

 

not drive piston to

verify that the motor is

 

 

 

 

end of stroke. Motor

generating force.

 

 

 

 

or drive is worn or

 

 

 

 

 

damaged.

 

EL00

Record

System

Record of power cycle

Indicates date and

n/a

 

 

Power On

(ON).

time when system was

 

 

 

 

 

started.

 

EM00

Record

System

Record of power cycle

Indicates date and

n/a

 

 

Power Off

(OFF).

time when system was

 

 

 

 

 

turned off.

 

EMIX

Advi-

Pump Off

The pumps are not

Pump power was

Start pumps by

 

sory

 

powered and are

turned off or an error

pressing pump start

 

 

 

unable to move.

occurred.

key on Advanced

 

 

 

 

 

Display module.

EQU0

Advi-

USB Idle

USB download

Data transfer is

Remove USB device

 

sory

 

process completed,

completed to the USB

from ADM.

 

 

 

drive may be removed.

device.

 

EQU1

Record

USB Sys.

Settings were

User installed USB

n/a

 

 

Settings

downloaded to USB

device in ADM USB

 

 

 

Down-

drive.

port.

 

 

 

loaded

 

 

 

332709B

15

Image 15
Contents ProMix PD2K Proportioner for Automatic Spray Applications Contents 0359 ModelsModel AC2000 High Pressure Identification Label Related Manuals Manual No DescriptionManual No Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Changing Materials Important Isocyanate ISO InformationIsocyanate Conditions Moisture Sensitivity of IsocyanatesTroubleshooting System TroubleshootingProblem Cause Solution B9BX Error Code TroubleshootingCode Type B9AX Efcm B9SX CAC# CA0XCddx USB EauxEBH# EbuxEmix EQU0EQU1 EQU5 EQU2EQU3 EQU4Mmux Qbdx QadxWsux QPD1SND1 SPD1Code Type Name Description Maintenance Error CodesPower Barrier Board Diagnostics Isolation Board Diagnostics Isolation Board DiagnosticsEnhanced Fluid Control Module Enhanced Fluid Control Module Efcm DiagnosticsPump Module Diagnostics Component or Indicator Function Pump Module DiagnosticsAdvanced Display Module Diagnostics 332709B Power Module Electrical SchematicsEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables and Modules Before Servicing RepairPressure Relief Procedure Without Color ChangeWith Color Change Install Key Token or Upgrade Token Repairing the Advanced Display Module ADM Replace the ADMReplace the Battery Isolation Board Cable Destination Connector Servicing the Control BoxReplacing the Isolation Board Detail of Isolation Board Cable Connections Replacing the Barrier Board Replacing the Barrier BoardReplacing the Enhanced Fluid Control Module Efcm Replacing the Barrier Board FusesReplacing the 24 Vdc Power Supply Replacing the 24 Vdc Power SupplyReplacing the 48 Vdc Pump Power Supply Replacing a Pump Control Module Replacing a Pump Control ModuleReplacing a Communication Gateway Module Replacing the Line Filter Replacing the Line FilterReplacing the Power Switch Replacing the Power SwitchInstalling a Pump Servicing the Fluid SectionRemoving a Pump Replacing a Solenoid Electrical Schematics,Replacing a Fan Module. See Electrical Schematics,Replacing a Fan Replacing a Solvent Flow Switch 332709B Proportioner Parts PartsPart Description Part No. AC1000 Low Pressure ProportionerGround Wire Washer 3/8CABLE, can Electrical Control Box Control Box PartsGrommet Power SupplyElectrical Control Box Part Description EnclosurePart Description Qty HARNESS, canMuffler Plate Connector 1/8Solenoid Manifold Parts Part No T772 Solenoid Manifold DescriptionPositive Displacement Metric Proportioner Technical DataGraco Standard Warranty Graco InformationFor Graco Canada Customers