| Troubleshooting |
|
|
|
|
|
|
Code | Type | Description | Problem | Cause | Solution |
|
|
|
|
|
|
EF0# | Alarm | Timeout | Pump tried but was not | Pump dose valves did | Verify air pressure |
|
| Startup | able to move to the | not actuate. | to solenoid valves. |
|
| Pump # | home position within |
| Verify the valves are |
|
|
| a specified amount of |
| actuating. |
|
|
| time. | Motor could not drive | Verify motor is driving |
|
|
|
| ||
|
|
|
| pumps and linear | the pump. |
|
|
|
| actuator. |
|
|
|
|
| Pump stroke length | Verify correct |
|
|
|
| is shortened by | assembly of linear |
|
|
|
| mechanical system | actuator and pump |
|
|
|
| tolerance. | piston rods. See pump |
|
|
|
|
| manual. |
EF1# | Alarm | Timeout | Pump tried but was not | Pump dose valves did | Visually inspect valves |
|
| Shutdown | able to move to the | not actuate. | to ensure they are |
|
| Pump # | park position within a |
| operating properly; |
|
|
| specified amount of |
| verify they have air |
|
|
| time. |
| pressure above 85 psi |
|
|
|
|
| (0.6 MPa, 6.0 bar). |
|
|
|
| Pump is filled with | Observe motor and |
|
|
|
| thick paint and could | drive assembly to |
|
|
|
| not drive piston to | verify that the motor is |
|
|
|
| end of stroke. Motor | generating force. |
|
|
|
| or drive is worn or |
|
|
|
|
| damaged. |
|
EL00 | Record | System | Record of power cycle | Indicates date and | n/a |
|
| Power On | (ON). | time when system was |
|
|
|
|
| started. |
|
EM00 | Record | System | Record of power cycle | Indicates date and | n/a |
|
| Power Off | (OFF). | time when system was |
|
|
|
|
| turned off. |
|
EMIX | Advi- | Pump Off | The pumps are not | Pump power was | Start pumps by |
| sory |
| powered and are | turned off or an error | pressing pump start |
|
|
| unable to move. | occurred. | key on Advanced |
|
|
|
|
| Display module. |
EQU0 | Advi- | USB Idle | USB download | Data transfer is | Remove USB device |
| sory |
| process completed, | completed to the USB | from ADM. |
|
|
| drive may be removed. | device. |
|
EQU1 | Record | USB Sys. | Settings were | User installed USB | n/a |
|
| Settings | downloaded to USB | device in ADM USB |
|
|
| Down- | drive. | port. |
|
|
| loaded |
|
|
|
332709B | 15 |