Graco 332709B important safety instructions Replacing the 24 Vdc Power Supply

Page 42

Repair

Replacing the 24 Vdc Power Supply

NOTICE

To avoid damaging the circuit boards when servicing the control box, wear Part No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

1.Follow the steps in Before Servicing, page 34.

2.Loosen the screws (124) and remove the enclosure cover (117, not shown).

3.Note the position of the power supply input and output wires. See Electrical Schematics, page 27. Disconnect the wires from the power supply (120).

4.Remove the screws (129) holding the power supply to the side of the enclosure. Remove the power supply.

5.Install the new power supply, using the screws (129).

6.Reconnect the wires to the positions as noted above.

NOTICE

Failure to follow the electrical schematic could result in damage to the electrical components.

7.Reinstall the cover (117) and tighten the screws (124).

8.Turn on power at the main circuit breaker.

9.Turn on the control box power switch.

NOTE: The green LED on the barrier board (106), the green power LED on the EFCM module (139), and the 24V green LED on each of the pump control modules (132) will light when operating.

Figure 27 Replacing the 24 Vdc Power Supply

42

332709B

Image 42
Contents ProMix PD2K Proportioner for Automatic Spray Applications Contents Models 0359Model AC2000 High Pressure Identification Label Related Manuals Manual No DescriptionManual No Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Moisture Sensitivity of Isocyanates Important Isocyanate ISO InformationIsocyanate Conditions Changing MaterialsTroubleshooting System TroubleshootingProblem Cause Solution B9AX Error Code TroubleshootingCode Type B9BXCA0X B9SXCAC# EfcmCddx Ebux EauxEBH# USBEmix EQU0EQU1 EQU4 EQU2EQU3 EQU5Mmux Qadx QbdxSPD1 QPD1SND1 WsuxMaintenance Error Codes Code Type Name DescriptionPower Barrier Board Diagnostics Isolation Board Diagnostics Isolation Board DiagnosticsEnhanced Fluid Control Module Efcm Diagnostics Enhanced Fluid Control ModulePump Module Diagnostics Pump Module Diagnostics Component or Indicator FunctionAdvanced Display Module Diagnostics 332709B Electrical Schematics Power ModuleEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables and Modules Repair Before ServicingPressure Relief Procedure Without Color ChangeWith Color Change Repairing the Advanced Display Module ADM Replace the ADM Install Key Token or Upgrade TokenReplace the Battery Isolation Board Cable Destination Connector Servicing the Control BoxReplacing the Isolation Board Detail of Isolation Board Cable Connections Replacing the Barrier Board Replacing the Barrier BoardReplacing the Barrier Board Fuses Replacing the Enhanced Fluid Control Module EfcmReplacing the 24 Vdc Power Supply Replacing the 24 Vdc Power SupplyReplacing the 48 Vdc Pump Power Supply Replacing a Pump Control Module Replacing a Pump Control ModuleReplacing a Communication Gateway Module Replacing the Line Filter Replacing the Line FilterReplacing the Power Switch Replacing the Power SwitchInstalling a Pump Servicing the Fluid SectionRemoving a Pump Electrical Schematics, Replacing a SolenoidModule. See Electrical Schematics, Replacing a FanReplacing a Fan Replacing a Solvent Flow Switch 332709B Parts Proportioner PartsPart No. AC1000 Low Pressure Proportioner Part DescriptionGround Wire Washer 3/8CABLE, can Control Box Parts Electrical Control BoxEnclosure Power SupplyElectrical Control Box Part Description GrommetPart Description Qty HARNESS, canMuffler Part No T772 Solenoid Manifold Description Connector 1/8Solenoid Manifold Parts PlateTechnical Data Positive Displacement Metric ProportionerGraco Standard Warranty Graco InformationFor Graco Canada Customers