Graco 332709B Repairing the Advanced Display Module ADM Replace the ADM

Page 36

Repair

Repairing the Advanced Display Module (ADM)

Replace the ADM

To replace the Advanced Display Module, disconnect the cable from the module and remove the module from the bracket. Install the new module on the bracket and attach the cable.

Figure 19 Replace the Advanced Display Module

3.Remove blue key token.

4.Insert and press black upgrade token (T) firmly into slot.

NOTE: There is no preferred orientation of the token.

Figure 21 Insert Token

5.Turn the power switch back on. The red indicator light (L) will flash until the new firmware is completely loaded.

6.Remove the token (T).

7.Replace the blue key token.

NOTE: The blue key token is required for proper operation.

8.Replace the token access panel.

Install Key Token or Upgrade Token

1.Shut off the PD2K power switch.

2.Remove the token access panel.

Figure 20 Remove Token Access Panel

36

332709B

Image 36
Contents ProMix PD2K Proportioner for Automatic Spray Applications Contents Models 0359Model AC2000 High Pressure Identification Label Related Manuals Manual No DescriptionManual No Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Important Isocyanate ISO Information Isocyanate ConditionsMoisture Sensitivity of Isocyanates Changing MaterialsTroubleshooting System TroubleshootingProblem Cause Solution Error Code Troubleshooting Code TypeB9AX B9BXB9SX CAC#CA0X EfcmCddx Eaux EBH#Ebux USBEmix EQU0EQU1 EQU2 EQU3EQU4 EQU5Mmux Qadx QbdxQPD1 SND1SPD1 WsuxMaintenance Error Codes Code Type Name DescriptionPower Barrier Board Diagnostics Isolation Board Diagnostics Isolation Board DiagnosticsEnhanced Fluid Control Module Efcm Diagnostics Enhanced Fluid Control ModulePump Module Diagnostics Pump Module Diagnostics Component or Indicator FunctionAdvanced Display Module Diagnostics 332709B Electrical Schematics Power ModuleEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables and Modules Repair Before ServicingPressure Relief Procedure Without Color ChangeWith Color Change Repairing the Advanced Display Module ADM Replace the ADM Install Key Token or Upgrade TokenReplace the Battery Isolation Board Cable Destination Connector Servicing the Control BoxReplacing the Isolation Board Detail of Isolation Board Cable Connections Replacing the Barrier Board Replacing the Barrier BoardReplacing the Barrier Board Fuses Replacing the Enhanced Fluid Control Module EfcmReplacing the 24 Vdc Power Supply Replacing the 24 Vdc Power SupplyReplacing the 48 Vdc Pump Power Supply Replacing a Pump Control Module Replacing a Pump Control ModuleReplacing a Communication Gateway Module Replacing the Line Filter Replacing the Line FilterReplacing the Power Switch Replacing the Power SwitchInstalling a Pump Servicing the Fluid SectionRemoving a Pump Electrical Schematics, Replacing a SolenoidModule. See Electrical Schematics, Replacing a FanReplacing a Fan Replacing a Solvent Flow Switch 332709B Parts Proportioner PartsPart No. AC1000 Low Pressure Proportioner Part DescriptionGround Wire Washer 3/8CABLE, can Control Box Parts Electrical Control BoxPower Supply Electrical Control Box Part DescriptionEnclosure GrommetPart Description Qty HARNESS, canMuffler Connector 1/8 Solenoid Manifold PartsPart No T772 Solenoid Manifold Description PlateTechnical Data Positive Displacement Metric ProportionerGraco Standard Warranty Graco InformationFor Graco Canada Customers