Graco 332709B important safety instructions Eaux, Ebh#, Ebux, Usb

Page 14

Troubleshooting

Code

Type

Description

Problem

Cause

Solution

 

 

 

 

 

 

DG0#

Alarm

No Stall

Pump failed the stall

Valve failure, seal

Replace inlet and

 

 

Down

test; did not stall on the

failure, worn rod or

outlet valve and seal

 

 

Pump #

downstroke.

cylinder.

for down stroke.

 

 

 

 

 

Replace piston and

 

 

 

 

 

throat seals. Replace

 

 

 

 

 

rod and cylinder as

 

 

 

 

 

necessary.

DH0#

Alarm

No Stall

Pump failed the stall

Valve failure, seal

Replace inlet and

 

 

Pump #

test; did not stall on

failure, worn rod or

outlet valve and seal

 

 

 

either the upstroke or

cylinder.

for up and down

 

 

 

the downstroke.

 

strokes. Replace

 

 

 

 

 

piston and throat

 

 

 

 

 

seals. Replace

 

 

 

 

 

rod and cylinder as

 

 

 

 

 

necessary.

DK0#

Alarm

Position

The pump was

 

Re-enable pump

 

 

Pump #

detected to be out

 

power to reset pump.

 

 

 

of position.

 

Make sure inlet supply

 

 

 

 

 

pressure is not too

 

 

 

 

 

high.

EAUX

Advi-

USB Busy

USB drive has been

Indicates USB port

Wait for USB Idle.

 

sory

 

inserted, download is

is uploading or

 

 

 

 

in progress.

downloading data.

 

EB00

Record

Stop

Record of a stop button

Indicates system stop

n/a

 

 

Button

press.

key on ADM was

 

 

 

Pressed

 

pressed.

 

EBH#

Record

Home

Record of pump

An indication on the

No action required.

 

 

Complete

homing is complete.

display that the pump

 

 

 

Pump #

 

completed the home

 

 

 

 

 

function

 

EBUX

Record

USB

USB drive was

Downloading/upload-

Replace the USB

 

 

drive was

removed while

ing data on USB was

device and begin

 

 

removed.

downloading or

interrupted by the USB

process again.

 

 

 

uploading.

device being removed.

 

EC00

Record

Setup

Record of changing

Indicates date and time

n/a

 

 

Value(s)

setup variables.

when setup values

 

 

 

Changed

 

were changed.

 

14

332709B

Image 14
Contents ProMix PD2K Proportioner for Automatic Spray Applications Contents Models 0359Model AC2000 High Pressure Identification Label Manual No Related ManualsManual No Description Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Moisture Sensitivity of Isocyanates Important Isocyanate ISO InformationIsocyanate Conditions Changing MaterialsProblem Cause Solution TroubleshootingSystem Troubleshooting B9AX Error Code Troubleshooting Code Type B9BXCA0X B9SXCAC# EfcmCddx Ebux EauxEBH# USBEQU1 EmixEQU0 EQU4 EQU2EQU3 EQU5Mmux Qadx QbdxSPD1 QPD1SND1 WsuxMaintenance Error Codes Code Type Name DescriptionPower Barrier Board Diagnostics Isolation Board Diagnostics Isolation Board DiagnosticsEnhanced Fluid Control Module Efcm Diagnostics Enhanced Fluid Control ModulePump Module Diagnostics Pump Module Diagnostics Component or Indicator FunctionAdvanced Display Module Diagnostics 332709B Electrical Schematics Power ModuleEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables and Modules Repair Before ServicingWith Color Change Pressure Relief ProcedureWithout Color Change Repairing the Advanced Display Module ADM Replace the ADM Install Key Token or Upgrade TokenReplace the Battery Replacing the Isolation Board Isolation Board Cable Destination ConnectorServicing the Control Box Detail of Isolation Board Cable Connections Replacing the Barrier Board Replacing the Barrier BoardReplacing the Barrier Board Fuses Replacing the Enhanced Fluid Control Module EfcmReplacing the 24 Vdc Power Supply Replacing the 24 Vdc Power SupplyReplacing the 48 Vdc Pump Power Supply Replacing a Pump Control Module Replacing a Pump Control ModuleReplacing a Communication Gateway Module Replacing the Line Filter Replacing the Line FilterReplacing the Power Switch Replacing the Power SwitchRemoving a Pump Installing a PumpServicing the Fluid Section Electrical Schematics, Replacing a SolenoidModule. See Electrical Schematics, Replacing a FanReplacing a Fan Replacing a Solvent Flow Switch 332709B Parts Proportioner PartsPart No. AC1000 Low Pressure Proportioner Part DescriptionCABLE, can Ground WireWasher 3/8 Control Box Parts Electrical Control BoxEnclosure Power SupplyElectrical Control Box Part Description GrommetMuffler Part Description QtyHARNESS, can Part No T772 Solenoid Manifold Description Connector 1/8Solenoid Manifold Parts PlateTechnical Data Positive Displacement Metric ProportionerFor Graco Canada Customers Graco Standard WarrantyGraco Information