Troubleshooting
Code | Type | Description | Problem | Cause | Solution |
|
|
|
|
|
|
DG0# | Alarm | No Stall | Pump failed the stall | Valve failure, seal | Replace inlet and |
|
| Down | test; did not stall on the | failure, worn rod or | outlet valve and seal |
|
| Pump # | downstroke. | cylinder. | for down stroke. |
|
|
|
|
| Replace piston and |
|
|
|
|
| throat seals. Replace |
|
|
|
|
| rod and cylinder as |
|
|
|
|
| necessary. |
DH0# | Alarm | No Stall | Pump failed the stall | Valve failure, seal | Replace inlet and |
|
| Pump # | test; did not stall on | failure, worn rod or | outlet valve and seal |
|
|
| either the upstroke or | cylinder. | for up and down |
|
|
| the downstroke. |
| strokes. Replace |
|
|
|
|
| piston and throat |
|
|
|
|
| seals. Replace |
|
|
|
|
| rod and cylinder as |
|
|
|
|
| necessary. |
DK0# | Alarm | Position | The pump was |
| |
|
| Pump # | detected to be out |
| power to reset pump. |
|
|
| of position. |
| Make sure inlet supply |
|
|
|
|
| pressure is not too |
|
|
|
|
| high. |
EAUX | Advi- | USB Busy | USB drive has been | Indicates USB port | Wait for USB Idle. |
| sory |
| inserted, download is | is uploading or |
|
|
|
| in progress. | downloading data. |
|
EB00 | Record | Stop | Record of a stop button | Indicates system stop | n/a |
|
| Button | press. | key on ADM was |
|
|
| Pressed |
| pressed. |
|
EBH# | Record | Home | Record of pump | An indication on the | No action required. |
|
| Complete | homing is complete. | display that the pump |
|
|
| Pump # |
| completed the home |
|
|
|
|
| function |
|
EBUX | Record | USB | USB drive was | Downloading/upload- | Replace the USB |
|
| drive was | removed while | ing data on USB was | device and begin |
|
| removed. | downloading or | interrupted by the USB | process again. |
|
|
| uploading. | device being removed. |
|
EC00 | Record | Setup | Record of changing | Indicates date and time | n/a |
|
| Value(s) | setup variables. | when setup values |
|
|
| Changed |
| were changed. |
|
14 | 332709B |