Graco 332709B important safety instructions Replacing the Power Switch

Page 47

Replacing the Power Switch

NOTICE

To avoid damaging the circuit boards when servicing the control box, wear Part No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

1.Follow the steps in Before Servicing, page 34.

2.Loosen the screws (124) and remove the enclosure cover (117).

3.Note the position of the power switch input and output wires. See Electrical Schematics, page 27. Disconnect the wires from the power switch (112).

4.Remove the switch terminal blocks (T), unscrew the retaining nut (N), and remove the switch.

5.Install the new switch.

6.Reconnect the wires to the positions as noted above.

Repair

NOTICE

Failure to follow the electrical schematic could result in damage to the electrical components.

7.Reinstall the cover (117) and tighten the screws (124).

8.Turn on power at the main circuit breaker.

Figure 32 Replacing the Power Switch

332709B

47

Image 47
Contents ProMix PD2K Proportioner for Automatic Spray Applications Contents 0359 ModelsModel AC2000 High Pressure Identification Label Manual No Related ManualsManual No Description Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Changing Materials Important Isocyanate ISO InformationIsocyanate Conditions Moisture Sensitivity of IsocyanatesProblem Cause Solution TroubleshootingSystem Troubleshooting B9BX Error Code TroubleshootingCode Type B9AXEfcm B9SXCAC# CA0XCddx USB EauxEBH# EbuxEQU1 EmixEQU0 EQU5 EQU2EQU3 EQU4Mmux Qbdx QadxWsux QPD1SND1 SPD1Code Type Name Description Maintenance Error CodesPower Barrier Board Diagnostics Isolation Board Diagnostics Isolation Board DiagnosticsEnhanced Fluid Control Module Enhanced Fluid Control Module Efcm DiagnosticsPump Module Diagnostics Component or Indicator Function Pump Module DiagnosticsAdvanced Display Module Diagnostics 332709B Power Module Electrical SchematicsEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables and Modules Before Servicing RepairWith Color Change Pressure Relief ProcedureWithout Color Change Install Key Token or Upgrade Token Repairing the Advanced Display Module ADM Replace the ADMReplace the Battery Replacing the Isolation Board Isolation Board Cable Destination ConnectorServicing the Control Box Detail of Isolation Board Cable Connections Replacing the Barrier Board Replacing the Barrier BoardReplacing the Enhanced Fluid Control Module Efcm Replacing the Barrier Board FusesReplacing the 24 Vdc Power Supply Replacing the 24 Vdc Power SupplyReplacing the 48 Vdc Pump Power Supply Replacing a Pump Control Module Replacing a Pump Control ModuleReplacing a Communication Gateway Module Replacing the Line Filter Replacing the Line FilterReplacing the Power Switch Replacing the Power SwitchRemoving a Pump Installing a PumpServicing the Fluid Section Replacing a Solenoid Electrical Schematics,Replacing a Fan Module. See Electrical Schematics,Replacing a Fan Replacing a Solvent Flow Switch 332709B Proportioner Parts PartsPart Description Part No. AC1000 Low Pressure ProportionerCABLE, can Ground WireWasher 3/8 Electrical Control Box Control Box PartsGrommet Power SupplyElectrical Control Box Part Description EnclosureMuffler Part Description QtyHARNESS, can Plate Connector 1/8Solenoid Manifold Parts Part No T772 Solenoid Manifold DescriptionPositive Displacement Metric Proportioner Technical DataFor Graco Canada Customers Graco Standard WarrantyGraco Information