Connecting the fluid hose
(Pressure feed guns only)
1.To control fluid pressure to the gun, install a fluid regulator on the fluid line.
2.Connect the fluid hose (J) to the gun fluid inlet (B) 
B
J
ti4854a
FIG. 5
Setup
Connecting the fluid supply
For packages that include fluid cups, use the following chart for installation instructions.
Cup attachment | Instruction Manual  | 
  | 
  | 
3M PPS  | 310693  | 
  | 
  | 
Gravity Cup  | 308792  | 
  | 
  | 
Siphon Cup  | 308792  | 
  | 
  | 
Pressure Cups  | 308791  | 
  | 
  | 
Positioning the Air Cap
Rotate the air cap as needed to achieve the desired spray pattern direction. To create a round pattern, turn the pattern air off by turning the pattern adjustment knob (25) fully clockwise. See FIG. 7.
3.Connect the other end of the fluid hose (J) to a regu- lated fluid supply line.
ti4839a
FIG. 6
10  | 310692C  |