Graco 310692C manual Replacing the fluid valve packings

Page 22

Replacing the fluid valve packings

1.Remove the fluid adjustment knob (21) and fluid spring (23).

2.Pull the fluid needle (13) out the back of the gun.

16

26

13

21

23 22 37 20 19

ti4850a

FIG. 33

3.Remove the fluid valve nut (19), air valve spring (22), and air valve assembly (26). Discard the air valve assembly. Using a mechanical pick, remove the u-cup packing (16) from the gun body.

Service

4.Place the new u-cup packing (16) on the packing installation tool (29), with the u-cup lips facing the tool as shown.

16

29

ti4851a

FIG. 34

5.Push the packing (16) into the back of the gun until a definite snap is felt.

6.Using a mechanical pick, remove the u-cup packing (20) and spacer (37) from the fluid valve nut (19). Be careful not to damage the seal surface or the nut's internal threads.

7.Using the packing installation tool (29), install the new u-cup packings (20) into the fluid valve nut (19). The u-cup lips must face toward the tool as shown. This will help apply even pressure to the u-cup lips and avoid damaging them.

19

20

ti4852a

FIG. 35

8.Push the u-cup packings (20) into the fluid valve nut (19) until a definite snap is felt.

22

310692C

Image 22
Contents Delta Spray XT Gun Manual Conventions ContentsRelated Manuals Fire and Explosion Hazard FE CED/IND General Pressurized Equipment HazardPressure feed spray guns with 1 quart pressure feed cup Selection ChartsPressure feed spray guns Siphon feed spray gunsGravity feed spray guns with 3M PPS gravity cup Gravity feed spray guns without gravity cupGravity feed spray guns with 16 oz. gravity cup Orifice sizeHvlp Guns Gun SelectionAir Caps Compliant GunsNozzle Orifice Fluid Nozzle, Needle, and Tip SelectionNozzle Assy Tip Kit Uses Top and bottom feed guns InstallationKey Connecting the air line SetupFlushing the gun Positioning the Air Cap Connecting the fluid hoseConnecting the fluid supply Pressure feed guns onlyAdjusting the Spray Pattern WariningSetup Applying the Fluid Pressure Relief ProcedureOperation IncorrectDaily Gun Maintenance General maintenanceGravity and Siphon Feed Guns Flushing and cleaningPressure Feed Guns Install the air cap retaining ring assembly 15 and air cap Ti4848a Troubleshooting Replacing the air and fluid packings Service Disassembling the gun Replacing the spray housing o-rings and packings Replacing the pattern adjustment valve packings Replacing the fluid valve packings Reassembling the gun Ti4849i Service 310692C Parts Airspray, HVLP, and Compliant GunsGun Assembly Spray HousingPart No. Description Qty Spatter or Specking Airspray Gun Spatter or Specking Airspray Gun Accessories Gravity Cup Holder Bracket Gun Air Regulator AssyGravity Cup SST Pressure Cup Kit 239802 with single air regulatorDisposable Polythylene Cup Liners SST Pressure Cup Kit 239803 with double air regulator3M PPS Paint Preparation System Fluid Shut Off SpringCategory Technical DataData Graco Standard Warranty Graco Information