Operation

Operation

Pressure Relief Procedure

WARNING

Follow Pressure Relief Procedure, page 13 when you stop spraying and before cleaning, checking, ser- vicing, or transporting equipment. Read warnings, page 3.

1.Turn off air and fluid supply.

2.Hold a metal part of the gun firmly to a grounded metal pail. Trigger the gun to relieve pressure.

1.To achieve the best results when applying fluid:

Keep the gun perpendicular and 6 to 8 inches (150 to 200 mm) from the object being sprayed.

Use smooth, parallel strokes across the surface to be sprayed with 50% overlap.

Incorrect

ti4843a

Correct

ti4836a

FIG. 11

Applying the Fluid

When using the HVLP spray gun, instead of a conven- tional airspray gun, you may need to use a slightly slower hand movement and make fewer passes with the gun to coat a part. This is due to the reduced spray velocity produced by lower HVLP air pressures, along with a larger fluid particle size because there is less air to blow off solvents than what is produced by conven- tional airspray. Take care to avoid runs or sags as you spray.

ti4842a

FIG. 12

310692C

13

Image 13
Contents Delta Spray XT Gun Manual Conventions ContentsRelated Manuals Pressurized Equipment Hazard Fire and Explosion Hazard FE CED/IND GeneralPressure feed spray guns Selection ChartsPressure feed spray guns with 1 quart pressure feed cup Siphon feed spray gunsGravity feed spray guns with 16 oz. gravity cup Gravity feed spray guns without gravity cupGravity feed spray guns with 3M PPS gravity cup Orifice sizeAir Caps Gun SelectionHvlp Guns Compliant GunsNozzle Orifice Fluid Nozzle, Needle, and Tip SelectionNozzle Assy Tip Kit Uses Top and bottom feed guns InstallationKey Connecting the air line SetupFlushing the gun Connecting the fluid supply Connecting the fluid hosePositioning the Air Cap Pressure feed guns onlyWarining Adjusting the Spray PatternSetup Operation Pressure Relief ProcedureApplying the Fluid IncorrectGeneral maintenance Daily Gun MaintenanceGravity and Siphon Feed Guns Flushing and cleaningPressure Feed Guns Install the air cap retaining ring assembly 15 and air cap Ti4848a Troubleshooting Replacing the air and fluid packings ServiceDisassembling the gun Replacing the spray housing o-rings and packings Replacing the pattern adjustment valve packings Replacing the fluid valve packings Reassembling the gun Ti4849i Service 310692C Airspray, HVLP, and Compliant Guns PartsGun Assembly Spray HousingPart No. Description Qty Spatter or Specking Airspray Gun Spatter or Specking Airspray Gun Accessories Gravity Cup Gun Air Regulator AssyGravity Cup Holder Bracket SST Pressure Cup Kit 239802 with single air regulator3M PPS Paint Preparation System SST Pressure Cup Kit 239803 with double air regulatorDisposable Polythylene Cup Liners Fluid Shut Off SpringCategory Technical DataData Graco Information Graco Standard Warranty