Graco 310692C manual Replacing the spray housing o-rings and packings

Page 20

6.Loosen the hex nut (9) with the gun tool (28).

9

ti4978a

FIG. 26

7.Remove the spray housing (2A) and insert (4).

2A 4

ti4830b

FIG. 27

Service

Replacing the spray housing o-rings and packings

1.With the spray housing (2A) removed from the insert (4), use a mechanical pick to remove the o-ring (2B) from the housing (2A).

2A 36 4

2B

ti4829b

FIG. 28

2. Remove o-ring (34) from the insert (4).

O-ring (2B) is slightly larger than o-ring (34).

3.Install a new o-ring (34) into the insert (4). Install a new o-ring (2B) into the housing (2A).

NOTE: To ease o-ring installation, place the insert

(4)into the spray housing (2B) to plug the end. Install one end of the o-ring into the groove in the housing, then press the rest of the o-ring into place.

20

310692C

Image 20
Contents Delta Spray XT Gun Related Manuals ContentsManual Conventions Fire and Explosion Hazard FE CED/IND General Pressurized Equipment HazardSelection Charts Pressure feed spray gunsPressure feed spray guns with 1 quart pressure feed cup Siphon feed spray gunsGravity feed spray guns without gravity cup Gravity feed spray guns with 16 oz. gravity cupGravity feed spray guns with 3M PPS gravity cup Orifice sizeGun Selection Air CapsHvlp Guns Compliant GunsNozzle Assy Tip Kit Uses Nozzle, Needle, and Tip SelectionNozzle Orifice Fluid Key InstallationTop and bottom feed guns Flushing the gun SetupConnecting the air line Connecting the fluid hose Connecting the fluid supplyPositioning the Air Cap Pressure feed guns onlyAdjusting the Spray Pattern WariningSetup Pressure Relief Procedure OperationApplying the Fluid IncorrectDaily Gun Maintenance General maintenancePressure Feed Guns Flushing and cleaningGravity and Siphon Feed Guns Install the air cap retaining ring assembly 15 and air cap Ti4848a Troubleshooting Disassembling the gun ServiceReplacing the air and fluid packings Replacing the spray housing o-rings and packings Replacing the pattern adjustment valve packings Replacing the fluid valve packings Reassembling the gun Ti4849i Service 310692C Parts Airspray, HVLP, and Compliant GunsPart No. Description Qty Spray HousingGun Assembly Spatter or Specking Airspray Gun Spatter or Specking Airspray Gun Accessories Gun Air Regulator Assy Gravity CupGravity Cup Holder Bracket SST Pressure Cup Kit 239802 with single air regulatorSST Pressure Cup Kit 239803 with double air regulator 3M PPS Paint Preparation SystemDisposable Polythylene Cup Liners Fluid Shut Off SpringData Technical DataCategory Graco Standard Warranty Graco Information