8.Install the trigger (10), pivot pin (17), wave washer (18), and screw (11). Torque the screw to
Service
12.Install the pattern adjustment valve assembly
17
18
11
10
ti4828a
FIG. 40
9.Apply a thin film of lubricant to the fluid nozzle seat and threads.
10.Trigger the gun while you install the fluid nozzle (12) with the gun tool (28). Torque the nozzle securely to 40
28 12
8
9
ti4849i
FIG. 41
11.Tighten the hex nut (9) securely to
ti4832a
FIG. 42
13.Tighten the packing screw (8) by turning the screw in until it touches the fluid packings, then tighten one full turn to
Tighten the screw 1/12 turn more (equal to half the distance between points on the hex head). See FIG. 41.
14.Trigger the gun to test the needle movement. If the needle does not return after the trigger is released or is slow in returning, loosen the packing screw (8) until the needle returns freely.
15.Replace seal (15B). Install the air cap (14), air cap retaining ring (15A), and seal (15B).
14 15A 15B
ti4980a
FIG. 43
16.Make sure the gun fluid packings are sealing prop- erly by spraying solvent at low pressure before fully pressurizing the gun with the fluid to be sprayed.
17.If the fluid packings leak, tighten the packing screw
(8) slightly and retest until the packings and fluid needle seal completely.
24 | 310692C |