Graco 262906 important safety instructions Spray Test Pattern Clearing Clogs

Page 10

Startup

Spray Test Pattern

Clearing Clogs

1.Spray test pattern. Adjust pressure to eliminate heavy edges.

Heavy

Edges

ti20413a

2.Use smaller tip size if pressure adjustment cannot eliminate heavy edges.

3.Hold gun perpendicular, 10-12 in. from surface. Spray back and forth; overlap by 50%.

ti20405a

4.Trigger gun before moving. Release before stop- ping. For additional spraying information, see gun manual 311861.

1.Release trigger, put safety ON. Rotate Spray Tip. Take safety OFF. Trigger gun to clear clog.

ti20404ati20409a

ti20419a

2.Put safety ON. Return Spray Tip to original position. Take safety OFF and continue spraying.

ti20404ati20410a

ti20419a

10

332161A

Image 10
Contents Operation Grounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Component Identification Pressure Relief Procedure Grounding Extension CordsSetup Startup PaintSpray Test Pattern Clearing Clogs Cleanup Perform Relieve Pressure Procedure,Power Flush Turn Spray-Prime/Drain valve to Spray OFF Technical Data Graco Standard Warranty Graco Information