Cleanup
This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Pro- cedure when you stop spraying and before cleaning, checking, or servicing the equipment.
1.Perform Relieve Pressure Procedure, page 6.
2.Remove guard and Spray Tip. For additional infor- mation, see gun manual.
ti20408a
3.Remove siphon tube set from paint. Wipe excess paint off outside of tubes.
4.Place siphon tube in flushing fluid. Use water for water base paint and mineral spirits for oil base paint. Place drain tube in waste pail.
Flush
Waste
ti2756b
5. Turn prime valve horizontal.
ti20407a
6.Hold gun against paint pail. Take trigger safety OFF. Trigger gun and increase pressure until the pump runs steady and flushing fluid appears.
1/4 Turn
ti20418a
Cleanup
7.Stop triggering gun. Move gun to waste pail, hold gun against pail, trigger gun to thoroughly flush system.
ti2599a
Waste
8.While continuing to trigger gun, turn prime valve down. Then, release gun trigger. Allow flushing fluid to circulate until fluid coming out of drain tube is clear.
ti20406a
9. Raise siphon tube above flushing fluid.
ti10744a
10.Close drain valve. Trigger gun into flushing pail to purge fluid from hose.
Flush
ti20407a
ti2599c
332161A | 11 |