Graco 262906 important safety instructions Off

Page 14

Cleanup

14.Circulate water through sprayer, into waste pail, for 20 seconds.

15.Turn power switch OFF.

ti5316a

/.

/&&

16.Close shutoff valve. Turn off water from garden hose.

18.Close drain valve. Turn power ON. Trigger gun into flushing pail to purge fluid from hose.

ti5303a

ON

ti20407a

Flush

OFF

19.Turn pressure control knob all the way down and power switch OFF. Unplug sprayer.

ti5316a

ti10445a

17.Unscrew shutoff valve from garden hose. Remove power flush adapter from suction tube. Install inlet strainer.

ti10448a

/.

/&&

ti20417a

ti4296a

14

332161A

Image 14
Contents Operation Grounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Component Identification Pressure Relief Procedure Grounding Extension CordsSetup Startup PaintSpray Test Pattern Clearing Clogs Cleanup Perform Relieve Pressure Procedure,Power Flush Turn Spray-Prime/Drain valve to Spray OFF Technical Data Graco Standard Warranty Graco Information