Graco 262906 important safety instructions Startup, Paint

Page 9

Startup

1. Turn pressure control to lowest pressure.

ti20417a

2. Turn power ON.

ti5303a

ON

OFF

Startup

6.Inspect for leaks. Do not stop leaks with hand or a rag! If leaks occur, perform Pressure Relief Procedure, page 6. Tighten fittings.

7.Place siphon tube in paint pail.

PAINT

TIA

8.Trigger gun again into flushing pail until paint appears.

3.Increase pressure 1/4 turn to start motor. Allow fluid to circulate through drain tube for 15 seconds.

1/4 turn

ti20418a

4.Turn prime valve horizontal.Take spray gun trigger safety OFF.

Flush

ti2599c

9.Move gun to paint pail and trigger for 20 seconds. Set gun safety ON.

ti5313b

0!).4

ti20407a

5.Hold gun against grounded metal flushing pail. Trig- ger gun and flush 1 minute.

Flush

TIAB

Do NOT place hands in front of tip.

10.Screw tip assembly onto gun. Tighten. For gun assembly instructions, see gun manual.

ti20416a

332161A

9

Image 9
Contents Operation Grounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Component Identification Pressure Relief Procedure Extension Cords GroundingSetup Paint StartupSpray Test Pattern Clearing Clogs Perform Relieve Pressure Procedure, CleanupPower Flush Turn Spray-Prime/Drain valve to Spray OFF Technical Data Graco Information Graco Standard Warranty