Graco 1030 dimensions Fire and Explosion Hazard

Page 3

The following are general Warnings related to the safe setup, use, maintenance and repair of this equipment. Additional, more specific warnings may be found throughout the text of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

DUse equipment only in well ventilated area.

DEliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic

drop clothes (potential static arc).

D Sprayer generates sparks. When flammable liquid is used in or near sprayer or for flushing or cleaning, keep sprayer at least 20 ft (6 m) away from explosive vapors.

DDo not clean with materials having flash points lower than 70_F (21_C). Use water--based materi-

als or mineral spirits type material only. For complete information about your fluid, request the MSDS from the fluid distributor or retailer.

DKeep work area free of debris, including solvent, rags and gasoline.

DDo not plug or unplug power cords or turn lights on or off when flammable fumes are present. D Ground equipment and conductive objects in work area. Read Grounding instructions.

DIf there is static sparking or you feel a shock, stop operating immediately. Do not use equipment until you identify and correct the problem.

SKIN INJECTION HAZARD

High pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

DDo not point gun at anyone or any part of the body. D Do not put your hand over the spray tip.

D Do not stop or deflect leaks with your hand, body, glove, or rag.

DEngage trigger lock when not spraying.

DFollow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking or servicing equipment.

PRESSURIZED ALUMINUM PARTS HAZARD

Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in this equipment. Such use could result in a serious chemical reaction, with the possibility of explosion, which could cause death, serious injury and/or substantial property damage.

309662 3

Image 3
Contents Model 234113, Series a Repair TexSpray 1030t FC309662 SpecificationsFire and Explosion Hazard Equipment Misuse Hazard TexSpray Gun Component DescriptionFlow and Air Control Prime ValveMaterial Air Requirements Minimum Compressor MaintenanceMonths Clean Air Flow Sensor as follows Compressor RequirementsProblem Cause Solution TroubleshootingTroubleshooting Problem Cause Solution Displacement Pump Repair RemovalRepair Pull piston rod 201 out of pump 3 2 to 3 inches 50 to 75 mm InstallationRepair Kit Clean and Inspect All PartsPump Repair Disassemble PumpGrease inside of throat Removal Bearing Housing & Connecting RodDo steps 2 -- 5 of Displacement Pump, Installa- tion, InstallationDrive Housing Remove five screws 99 and lockwashers 43 and pinion assembly Pinion Assembly/Rotor/Field/Shaft/ClutchCollar Clutch Housing Engine Sprayer Wiring DiagramParts Sprayer Ref No. Part No Kit Parts Flow ControlDetail C TI10246e 309662 Parts Dump ManifoldDetail a Detail BModel 235166, Series a Parts Displacement PumpRef No Pinion Housing Repair Kit Ref No Drive Housing Repair KitAir And Material Hose Kit 235737 AccessoriesDimensions Technical DataFor Graco Canada Customers Graco Warranty and Disclaimers