Graco 1030 Maintenance, Compressor Requirements, Material Air Requirements Minimum Compressor

Page 6

Component Description

Compressor Requirements

NOTE: This sprayer requires an external air compres- sor.

CAUTION

Install an air filter on external air compressor to reduce contamination to spray system.

Air compressor range: 10 scfm to 35 scfm, 30 to 140 psi (0.2--0.97 MPa, 2 to 9.7 bar)

Material

Air Requirements*

Minimum

 

 

Compressor

 

 

Size*

 

 

 

Elastomerics

30 scfm at 90 psi

15 HP

(textured)

(0.84 m3/min at

 

 

0.63 MPa, 6.3 bar)

 

 

 

 

Simulated

20 scfm at 60 psi

5.5 HP

Accoustical

(0.56 m3/min at

 

 

0.42 MPa, 4.2 bar)

 

 

 

 

Splatter Coat

15 scfm at 40 psi

8 HP

and

(0.42 m3/min at

 

Knockdown

0.28 MPa, 2.8 bar)

 

 

 

 

Orange Peel

20 scfm at 60 psi

8 HP

 

(0.56 m3/min at

 

 

0.42 MPa, 4.2 bar)

 

 

 

 

*Material, temperature and volume affect cfm needed to properly atomize material.

Maintenance

CAUTION

DFor detailed engine maintenance and specifica- tions, refer to separate HONDA engine manual.

DClose black fuel shutoff lever whenever you are transporting sprayer to prevent fuel from flooding engine.

DKeep sprayer upright and level when operating it and when transporting it. This prevents crankcase oil from leaking into combustion chamber, which makes startup very difficult.

Daily: Check engine oil level and fill as needed.

Daily: Check and fill gas tank.

Daily: Check sprayer air filter, clean and replace element as needed.

6 309662

After first 20 hours of operation and each 100 hours thereafter: Change oil.

Weekly: Remove engine air filter cover and clean element. In very dusty environments, check filter daily. Replace element as needed. Replacement elements can be purchased from your local HONDA dealer.

Spark plug: Use only a (NGK) BP6ES or BPR6ES plug. Gap plug to 0.025 to 0.030 in. (0.7 to 0.8 mm). Always use a spark plug wrench.

6 months: Clean Air Flow Sensor as follows:

1.Fig. 3. Loosen adapter (A). Pull down quick re- lease (C) and swing out flow sensor regulator. Disconnect connector (B).

2.Remove inlet fitting (D), retainer ring (E), piston (F) and spring (G) from flow sensor regulator (H).

CAUTION

Do not scratch or nick piston (F) or inside of flow sensor regulator (H).

3.Clean all parts (D, E, F, G). Clean inside of (H) with a pipe cleaner.

4.Assemble all parts and install flow sensor regula- tor.

Flow

C

Sensor Regulator

 

B

A

D E

F G

H

 

 

 

Flow

Fig. 3

 

 

Sensor Regulator ti4366a

Image 6
Contents Repair TexSpray 1030t FC Model 234113, Series aSpecifications 309662Fire and Explosion Hazard Equipment Misuse Hazard Prime Valve Component DescriptionFlow and Air Control TexSpray GunCompressor Requirements MaintenanceMonths Clean Air Flow Sensor as follows Material Air Requirements Minimum CompressorTroubleshooting Problem Cause SolutionTroubleshooting Problem Cause Solution Displacement Pump Repair RemovalRepair Installation Pull piston rod 201 out of pump 3 2 to 3 inches 50 to 75 mmDisassemble Pump Clean and Inspect All PartsPump Repair Repair KitGrease inside of throat Installation Bearing Housing & Connecting RodDo steps 2 -- 5 of Displacement Pump, Installa- tion, RemovalDrive Housing Pinion Assembly/Rotor/Field/Shaft/Clutch Remove five screws 99 and lockwashers 43 and pinion assemblyCollar Clutch Housing Sprayer Wiring Diagram EngineParts Sprayer Ref No. Part No Parts Flow Control KitDetail B Parts Dump ManifoldDetail a Detail C TI10246e 309662Parts Displacement Pump Model 235166, Series aPinion Housing Repair Kit Ref No Drive Housing Repair Kit Ref NoAccessories Air And Material Hose Kit 235737Technical Data DimensionsGraco Warranty and Disclaimers For Graco Canada Customers