Graco 1030 dimensions Troubleshooting, Problem Cause Solution

Page 7

Troubleshooting

WARNING

To reduce risk of injury due to sprayer starting unexpectedly, shut off engine before performing checks or service.

Check everything in chart before disassembling sprayer.

PROBLEM

CAUSE

SOLUTION

 

 

 

 

 

Engine does not start

Engine switch not ON

Turn engine switch ON

 

 

 

 

 

 

Out of gas

Fill gas tank

 

 

 

 

 

 

Spark plug cable disconnected or

Connect spark plug cable or replace

 

 

spark plug damaged

spark plug

 

 

 

 

 

 

Oil seepage into combustion

Remove spark plug. Pull starter rope 3 or

 

 

chamber

4 times. Clean and install spark plug. Try

 

 

 

to start. Keep sprayer upright and do not

 

 

 

overfill engine crankcase to avoid oil

 

 

 

seepage.

 

 

 

 

 

 

Oil level low

Add oil to engine crankcase

 

 

 

 

 

Engine operates, but

Flow control set to OFF

Set flow control to PRIME mode or LOW/

 

displacement pump does not

 

MED/HIGH while triggering gun

 

 

 

 

 

 

Air compressor not on or insufficient

Start air compressor

 

 

air flow from compressor

Increase SCFM or compressor size.

 

 

 

Check air passages and tips for obstruc-

 

 

 

tions.

 

 

 

Check air filter element for clogs.

 

 

 

 

 

 

Air pressure set to low

Check display for air pressure. System

 

 

 

requires a minimum of 40 psi (0.28 MPa,

 

 

 

2.8 bar) to operate. Increase pressure by

 

 

 

adjusting air control knob.

 

 

 

 

 

 

Sprayer engine RPM too low

Increase engine speed

 

 

 

 

 

 

Clutch connector into back of circuit

Check and ensure a tight connection.

 

 

board is loose.

 

 

 

 

 

 

 

Air filter dirty

Clean or replace filter element.

 

 

 

 

 

 

Air flow sensor dirty or damaged

Check air filter.

 

 

 

Clean air flow sensor (see page 4) or re-

 

 

 

place as needed.

 

 

 

 

 

 

Air transducer failed

Check display for correct air pressure

 

 

 

reading. Replace circuit board as need-

 

 

 

ed.

 

 

 

 

 

 

Fluid transducer failed

Check connection at circuit board.

 

 

 

Replace fluid transducer.

 

 

 

 

 

 

Clutch not engaging

Worn or damaged clutch. See page 18.

 

 

 

Fluid transducer failure. Air transducer

 

 

 

failure.

 

 

 

 

 

 

Displacement pump rod seized by

Service pump. See page 10.

 

 

dry coating

 

 

 

 

 

 

 

 

309662

7

Image 7
Contents Model 234113, Series a Repair TexSpray 1030t FC309662 SpecificationsFire and Explosion Hazard Equipment Misuse Hazard TexSpray Gun Component DescriptionFlow and Air Control Prime ValveMaterial Air Requirements Minimum Compressor MaintenanceMonths Clean Air Flow Sensor as follows Compressor RequirementsProblem Cause Solution TroubleshootingTroubleshooting Problem Cause Solution Removal Displacement Pump RepairRepair Pull piston rod 201 out of pump 3 2 to 3 inches 50 to 75 mm InstallationRepair Kit Clean and Inspect All PartsPump Repair Disassemble PumpGrease inside of throat Removal Bearing Housing & Connecting RodDo steps 2 -- 5 of Displacement Pump, Installa- tion, InstallationDrive Housing Remove five screws 99 and lockwashers 43 and pinion assembly Pinion Assembly/Rotor/Field/Shaft/ClutchCollar Clutch Housing Engine Sprayer Wiring DiagramParts Sprayer Ref No. Part No Kit Parts Flow ControlDetail C TI10246e 309662 Parts Dump ManifoldDetail a Detail BModel 235166, Series a Parts Displacement PumpRef No Pinion Housing Repair Kit Ref No Drive Housing Repair KitAir And Material Hose Kit 235737 AccessoriesDimensions Technical DataFor Graco Canada Customers Graco Warranty and Disclaimers