Basic Troubleshooting / 基本故障排除 / 기본적인 문제 해결
Problem |
| What To Check | What To Do |
| (If check is OK, go to next check) | (When check is not OK, refer to this column) | |
|
|
|
|
|
|
|
|
Low Fluid Output | 1. | Worn or clogged spray tip. | Relieve pressure, page 15. Replace or clean tip. |
|
|
| Refer to gun instruction manual, 313347. |
|
|
|
|
| 2. | Verify pump does not continue | Service Pump, page 58. |
|
| to stroke when gun trigger |
|
|
| is released. |
|
|
|
|
|
| 3. | Prime valve leaking. | Relieve pressure, page 15. Then repair Prime Valve, |
|
|
| page 60. |
|
|
|
|
| 4. | Suction hose connections. | Tighten any loose connections. Check |
|
|
| on suction hose tube. |
5.Electric supply with volt meter. Reset building circuit breaker; replace building fuse.
Meter must read | Repair electrical outlet or try another outlet. | |
Vac models and |
| |
for 240 | Vac models. Low voltages |
|
reduce sprayer performance. |
|
6.Extension cord size and length. Replace with a correct, grounded extension cord,
page 12.
7. | Leads from motor to circuit | Be sure male terminal pins are centered and firmly |
| board for damaged or loose | connected to female terminals. Replace any loose |
| wire connectors. Inspect wiring | terminals or damaged wiring. Securely reconnect |
| insulation and terminals for | terminals. |
| signs of overheating. |
|
|
|
|
8. | Worn motor brushes which must | Replace Motor, page 33. |
| be 1/4 in. (6 mm) minimum. |
|
|
|
|
9. | Motor brushes binding in brush | Clean brush holders. Remove carbon dust by using |
| holders. | compressed air to blow out brush dust. |
|
|
|
10. | Low stall pressure. Turn pressure | Replace Pressure Control Assembly, page 60. |
| control knob fully clockwise. |
|
|
|
|
11. | Motor armature for shorts | Replace Motor, page 33. |
| by using an armature tester |
|
| (growler) or perform spin test, |
|
| page 54. |
|
|
|
|
12. | Pump is primed. | Prime pump, page 19. |
|
|
|
13. | Inlet and outlet balls are not | Inlet: Remove suction tube and place pencil into inlet |
| stuck. | housing to dislodge ball and allow proper priming. |
|
| Outlet: Insert screwdriver in slot and remove |
|
| |
|
| with a 3/4 in. socket. Remove and clean assembly. |
313797C | 37 |