Shutdown and Cleaning

Triggering Gun

Aiming Gun

Pull trigger after starting stroke. Release trig- ger before end of stroke. Gun must be moving when trigger is pulled and released.

Aim tip of gun at bottom edge of previous stroke, overlapping each stroke by half.

TIA

TIA

Shutdown and Cleaning

If spraying lacquers, purchase Lacquer Conversion Kit 248202. Follow Shutdown and Cleaning procedures for oil-based materials.

Pail Flushing

• For short term shutdown periods (up to 2 days) refer to Short Term Storage, page 20.

3. Turn Spray-Prime/Drain Valve to PRIME.

02)-%

• For flushing after spraying oil-based

coatings, use compatible oil-based

flushing fluid or mineral spirits. Read

Priming, Oil- or Water-based Materi-

als, page 10.

• For flushing after spraying water-based

coatings, use water. Read Priming, Oil-

or Water-based Materials, page 10 or

4.Turn Pressure Control knob to the left (counter-clockwise) to

minimum pressure.

5. Trigger gun into waste

WLD

Power Flush, page 17.

1. Turn power switch OFF. Lift suction tube and prime tube from paint pail. Let them drain into paint for a while.

WLD

pail to relieve pressure in hose.

6. Remove tip and guard assembly from gun and place in flushing fluid.

&,53().' &,5)$

TIA

2.Place suction tube in pail filled with flushing fluid and place prime tube in waste pail.

16

309225W

Image 16
Contents Airless Sprayers Specifications ModelsFire and Explosion Hazard Equipment Misuse Hazard Grounding and Electric Requirements InstallationThermal Overload Component Identification Sprayers Operation Pressure Relief ProcedureTrigger Lock Setup SetupPriming Oil- or Water-based MaterialsPump Check Valves DX ModelInstalling Tip and Base Unclogging Spray TipTip Selection Selecting Tip Hole SizeReversible Tip Selection Chart Choosing the Correct Tip for the JobAdjusting Pressure Spraying TechniquesPreventing Excessive Tip Wear Getting Started With Basic TechniquesTriggering Gun Shutdown and CleaningPail Flushing Power Flush Closed Cleaning InstaClean Fluid Filter XR models Gun Fluid FilterShort Term Storage up to Long Term Storage moreStowing Sprayer Troubleshooting Read Pump does not prime section Clean or replace InstaClean fluid Grounding and Electrical Maintenance and Service TipsCaring for Sprayer Pump PackingsTechnical Data Height with folded Handle 26 in cmGraco Standard Warranty For Graco Canada Customers