Shutdown and Cleaning

9.Turn lever to close power flush attachment.

10.Unscrew inlet screen from suction tube. Place inlet screen in waste pail.

CLOSED

TIA

TIA

Step 15 is for returning paint in hose back to paint pail. One 50-ft (15-m) hose holds approximately 1-quart (1-liter) of paint.

15.

a. Pull and hold gun trigger. Point gun into

paint pail.

b. Turn power switch ON to begin pumping

paint in hose back into paint pail.

c. When water comes out of gun, continue

to trigger gun, aiming gun into waste

pail.

16. Continue triggering gun into waste pail for

1-2 minutes, until relatively clear water

comes out of gun.

11.Connect garden hose to suction tube with Power Flush attach- ment. Leave prime tube in waste pail.

TIA

TIA

12. Turn Spray-Prime/Drain valve to SPRAY.

302!9

13. Align arrow on sprayer with pail symbol on Pressure Control knob until pump starts.

TIA

14.Open lever on Power Flush attachment.

OPEN

TIA

17. Turn Spray-Prime/Drain valve

to PRIME.

02)-%

18.Circulate water through

sprayer, into waste pail, for 20 seconds.

19. Turn power switch OFF.

WLD

20.Close Power Flush attachment. Turn off garden hose.

CLOSED

21.Unscrew Power Flush attach- ment from suction tube.

TIA

18

309225W

Image 18
Contents Airless Sprayers Specifications ModelsFire and Explosion Hazard Equipment Misuse Hazard Installation Grounding and Electric RequirementsThermal Overload Component Identification Sprayers Pressure Relief Procedure OperationTrigger Lock Setup SetupPriming Oil- or Water-based MaterialsPump Check Valves DX ModelInstalling Tip and Base Unclogging Spray TipTip Selection Selecting Tip Hole SizeReversible Tip Selection Chart Choosing the Correct Tip for the JobPreventing Excessive Tip Wear Adjusting PressureSpraying Techniques Getting Started With Basic TechniquesShutdown and Cleaning Triggering GunPail Flushing Power Flush Closed Cleaning InstaClean Fluid Filter XR models Gun Fluid FilterShort Term Storage up to Long Term Storage moreStowing Sprayer Troubleshooting Read Pump does not prime section Clean or replace InstaClean fluid Grounding and Electrical Caring for Sprayer Maintenance and ServiceTips Pump PackingsTechnical Data Height with folded Handle 26 in cmGraco Standard Warranty For Graco Canada Customers