Graco Inc 309225W specifications Power Flush

Page 17

7. Turn power switch ON.

WLD

8. Slowly align arrow on

 

sprayer with Pail

 

symbol on Pressure

 

Control knob until

 

pump starts.

TIA

9.Flush until approximately 1/3 of the flushing fluid is emptied from the pail.

10. Turn power switch OFF.

TIA

 

Turn Spray-Prime/Drain

 

valve to SPRAY.

 

302!9

11.To preserve paint in hose, trigger gun into paint pail to expel the remaining paint.

12.Turn power switch ON. Continue to trigger gun until you see flushing fluid starting to come out of gun nozzle. Release trigger.

13.Move gun to waste pail and trigger it to flush pump, hose and gun into waste pail. Continue until remaining flushing fluid is gone from flushing fluid pail.

14.Fill unit with Pump Armor

storage fluid. Read Long Term Storage, page 20.

TIA

0UMPM!RMOR

Shutdown and Cleaning

Power Flush

Power flushing is a faster method of flushing. It can only be used after spraying water-based coatings.

1. Turn power switch OFF. Lift suction tube and prime tube from paint pail. Let them drain into paint for a while.

WLD

2.Place suction and prime tube in waste pail.

3.Turn Spray-Prime/Drain Valve

to PRIME.

02)-%

4.Turn Pressure Control knob to the left (counter-clock- wise) to minimum pressure.

WLD

5.Trigger gun into waste pail to relieve pres- sure in hose.

6.Remove tip and guard assembly from gun and place in flushing fluid.

&,53().' &,5)$

TIA

7.Screw power flush attach- ment to garden hose. Open valve.

8. Turn on water. Rinse paint

OPEN

 

off suction tube, prime tube TIA

 

and inlet screen.

 

309225W

17

Image 17
Contents Airless Sprayers Models SpecificationsFire and Explosion Hazard Equipment Misuse Hazard Thermal Overload InstallationGrounding and Electric Requirements Component Identification Sprayers Trigger Lock Pressure Relief ProcedureOperation Setup SetupOil- or Water-based Materials PrimingDX Model Pump Check ValvesUnclogging Spray Tip Installing Tip and BaseSelecting Tip Hole Size Tip SelectionChoosing the Correct Tip for the Job Reversible Tip Selection ChartSpraying Techniques Adjusting PressurePreventing Excessive Tip Wear Getting Started With Basic TechniquesPail Flushing Shutdown and CleaningTriggering Gun Power Flush Closed Gun Fluid Filter Cleaning InstaClean Fluid Filter XR modelsLong Term Storage more Short Term Storage up toStowing Sprayer Troubleshooting Read Pump does not prime section Clean or replace InstaClean fluid Grounding and Electrical Tips Maintenance and ServiceCaring for Sprayer Pump PackingsHeight with folded Handle 26 in cm Technical DataFor Graco Canada Customers Graco Standard Warranty